When treating pigmented lesions with بيكو ثانية أو Q-switched (nanosecond) lasers, the ability to correctly judge the رد فعل نقطة النهاية is one of the most important clinical skills. Many practitioners adjust fluence based on whitening alone, but without understanding the mechanism of whitening, it’s easy to overtreat, burn the epidermis, and increase the risk of فرط التصبغ التالي للالتهاب (PIH).

In this guide, Mico Aes explains:

  • Why whitening occurs
  • How cavitation affects epidermal reactions
  • Differences between picosecond and nanosecond pulse widths
  • How to choose safe endpoint reactions for each lesion type

This article is designed for dermatologists, laser therapists, clinic owners, and distributors seeking deeper professional knowledge.


1. What Is the “Endpoint Reaction” in Pigment Laser Treatment?

In pigment-targeting lasers (pico & Q-switched), the typical endpoint for epidermal pigmented lesions is:

✔ Immediate whitening of the lesion

Long-pulse lasers may also treat pigment, but their endpoint appears differently—usually:

✔ Slight darkening after several minutes

The degree of whitening can vary:

  • Light white
  • Gray-white
  • Frost-white
  • Porcelain-white

The darker and more melanin-dense the lesion is, the more obvious the whitening becomes.


2. Why Does Whitening Occur? The Real Scientific Mechanism

Most whitening reactions are misunderstood. Whitening is not pigment turning white.

Whitening is an optical scattering effect produced by laser-induced vacuoles.

Here’s how it happens:

Step 1 — Laser absorption by melanin

Short-pulse lasers (ns and ps) deliver energy faster than thermal relaxation time.

Step 2 — Rapid thermoelastic expansion

Melanosomes heat instantly and expand.

Step 3 — Mechanical shockwave formation

This creates a powerful photoacoustic / photothermal-mechanical effect.

Step 4 — Cavitation and tissue disruption

Shockwaves rupture melanosomes and surrounding tissue, forming vacuoles in:

  • البشرة
  • Dermal–epidermal junction (DEJ)

Step 5 — Light scattering

The vacuoles scatter incident light → the lesion appears white.

The bigger the vacuole, the whiter the reaction.

Circular-vacuoles-formed-in-the-epidermis-after-irradiation-with-a-532nm-Q-switched-laser-for-solar-lentigines
Circular vacuoles formed in the epidermis after irradiation with a 532nm Q-switched laser for solar lentigines
Large-bubbles-formed-on-the-epidermis-by-755nm-nanosecond-laser-2.
Large bubbles formed on the epidermis by 755nm nanosecond laser (2)

3. Picosecond vs Nanosecond Laser: Why Their Whitening Looks Different

A key factor in cavitation size is عرض النبض.

Nanosecond Lasers (Q-Switched)

  • Produce larger cavitation vacuoles
  • Stronger scattering
  • Whitening is more obvious
  • Frost-white appears easily
  • Higher PIH risk if overtreated

ليزر بيكو ثانية

  • Create smaller vacuoles
  • Whitening is milder → ideal endpoint = gray-white
  • Frost-white suggests over-energy أو excess overlapping
  • Lower thermal injury but easier to overtreat with high fluence

This explains why manufacturers recommend:

Why-cant-the-endpoint-reaction-of-picosecond-laser-be-frosty-white.
Why can’t the endpoint reaction of picosecond laser be frosty white

✔ Pico ideal endpoint: Light gray-white

✘ Frost-white: NOT ideal for pico


4. Why You Must Avoid Frost-White with Picosecond Lasers

Frost-white during pico treatment indicates:

  • Fluence too high
  • Shockwave intensity excessive
  • Cavitation too large
  • Tissue damage increased

This significantly raises the risk of:

  • PIH
  • Prolonged erythema
  • Micro-epidermal injury
  • Scarring in sensitive skin types

For safe and effective pico treatment:

➡ Aim for light gray-white only.


5. Clinical Parameter Setting Principles for Pico & Q ليزر تبديل

✔ 1. Treat epidermal lesions conservatively

Especially solar lentigines and freckles—the most PIH-prone lesions.

✔ 2. Do not chase “one-session clearance”

High fluence may clear pigment faster, but PIH makes overall results worse.

✔ 3. Pico → small cavitation → choose lower energy

  • Endpoint = pale gray-white
  • Avoid multi-pass overlapping

✔ 4. Nano → stronger cavitation → customize per lesion

  • Light white for solar lentigo
  • Frost-white may be acceptable for pigment-rich lesions
  • Reduce fluence in Fitzpatrick III–V patients

✔ 5. Understand melanin density control

When melanin is abundant, even low energy may produce strong whitening.


6. Summary: Choosing the Right Endpoint Reaction

نوع الليزرCavitation SizeIdeal EndpointAvoidPIH Risk
PicosecondSmallGray-whiteFrost-whiteواسطة
Q-Switched (ns)LargeLight whiteExcessive frost-whiteعالي
Long-pulse pigment lasersالحد الأدنىSlight darkeningلا أحدقليل

الوجبات السريعة الرئيسية

  1. Whitening is caused by light scattering from epidermal vacuoles.
  2. Larger vacuoles → stronger scattering → whiter appearance.
  3. Picosecond lasers should not produce frost-white under correct settings.
  4. Choosing the right endpoint reaction is critical for preventing PIH.
  5. Nanosecond lasers require more caution in darker skin types.

Why Clinics Choose Mico Aes Pigment Lasers

As a trusted global manufacturer, ميكو آيس provides professional-grade devices that help clinics achieve safer and more consistent pigment removal results:

✔ Stable medical-grade laser energy output

(755/1064/532nm pico, Q-switched, and hybrid systems available)

✔ Advanced beam homogenization

Reduces hot spots, lowers PIH risk.

✔ Proven clinical efficacy

Used by dermatology clinics, med spas, and distributors worldwide.

✔ Lifetime technical support

1-on-1 training + parameter guidance.

✔ OEM/ODM for distributors

Support for branding, manuals, marketing materials, and product customization.


Ready to Upgrade Your Laser Portfolio?

Whether you operate a clinic or distribute aesthetic devices, Mico Aes offers the latest in picosecond, Q-switched, and fractional laser technology.

📩 موقع إلكتروني: https://micoaes.com/product-category/laser-tattoo-removal/
📞 واتساب: +86 18506287248
🌍 Global Shipping | CE/FDA/ISO Certified | OEM & Distributor Support

المزيد من المدونات ذات الصلة

دليل ليزر بيكو للبقع الكبيرة منخفض الطاقة: علاج آمن للبشرة لكل أنواع البشرة

ما هي ليزر Q-switch و Yag للعناية بالبشرة المهنية؟

Q-switched ND: YAG ليزر للآفات المصطبغة: علاج melasma ، النمش ، والولادات

ما مدى فعالية ND: ليزر YAG لعلاج Melasma؟

ليزر Q-Switched Pico: الدليل الكامل للآلية ونطاق العلاج & ملاحظات السلامة

ليزر بيكو أم ليزر ثاني أكسيد الكربون – أيهما أفضل لإزالة الوشم؟

Fractional CO₂ + PicoWay: مجموعة عملية تدر الإيرادات من أجل إعادة تسطيح أعمق & التحكم في الصباغ

الدليل السريري لليزر البيكو وفقًا لتفاعلات نقطة النهاية الجلدية: تحسين البيكو & أداء الليزر بالنانو ثانية

Q switched laser: آلية ، مؤشرات ، موانع ، معلمات & احتياطات

وقت التعافي بالليزر Q-Switch: ما يمكن توقعه وكيفية تسريع عملية الشفاء

Portable Picoway picosecond Machine Operation

ما هي أفضل آلة ليزر لإزالة الوشم الاحترافية في عام 2025؟

رائع! شارك هذا المقال

محتويات المادة

المدونات الأكثر شعبية

عن المؤلف

إيلا من ميكو آيس

ايلا تشان

مرحبًا بكم في قناة مدونتي، حيث أمتلك أكثر من 10 سنوات من الخبرة في صناعة آلات التجميل. من آلات الصالون إلى أجهزة التجميل للاستخدام المنزلي، سأرشدك خلال أحدث التطورات، وأقدم معلومات موثوقة، وأساعدك على اتخاذ قرارات مستنيرة. انضم إلي في هذه الرحلة التحويلية لإطلاق العنان لإمكانيات جمالك الحقيقية بقوة التكنولوجيا.

عرض المزيد من المنتجات

حول ميكو آيس

شعار ميكو AES-3

Mico Aes هي شركة متخصصة في تصنيع أجهزة التجميل منذ أكثر من 15 عامًا في الصين، لدينا جميع أنواع الآلات الخاصة بـ med spa وIPL وآلات إزالة الشعر بالليزر، وآلات hifu، وآلات النحت، وآلات تحلل الدهون بالتبريد، وآلات ليزر بيكو، وآلات rf، وآلات التجويف. وأجهزة الوجه المائية وأجهزة العلاج بالضوء LED وبعض أجهزة التجميل للاستخدام الشخصي. مزيد من التفاصيل، أو اتصل بنا.

عربة التسوق
انتقل إلى أعلى