Guida laser Pico a spot grande a basso consumo energetico: trattamento sicuro per ogni tipo di pelle

Figure-1.-Before-and-after-comparison-of-LFHSS-1064-nm-nanosecond-laser-treatment-for-melasma-a-before-treatment-b-after-treatment.png

Ensuring optimal treatment outcomes while minimizing adverse reactions has always been a central challenge in medical aesthetics. Traditional high-fluence laser protocols are effective but frequently associated with complications such as post-inflammatory hyperpigmentation (PIH) and barrier disruption—especially in melanin-rich Asian skin types.

Low-Fluence, High-Spot-Size (LFHSS) laser technology offers a safer alternative by combining gentle thermal effects con precise pigment targeting. Today, this technique is widely applied in 1064 nm / 755 nm, nanosecondo E picosecondo piattaforme.

This article provides a comprehensive scientific and clinical overview of LFHSS: its origin, standardized definition, indication-specific parameters, treatment precautions, and contraindications—offering physicians a structured and evidence-based protocol.


1. Origin and Standard Definition

1.1 Historical Background

LFHSS can be traced back to the mid-2000s, when Korean dermatologists first applied large spot sizes and low fluence con Q-switched Nd:YAG 1064 nm nanosecond lasers for melasma management—coining the term Laser Toning.

The approach quickly gained global popularity and later inspired technologies such as “Whitening Toning,” “Carbon Peeling,” and other low-fluence programs.

With device evolution, LFHSS expanded to 755 nm nanosecond and picosecond lasers, enabling more precise pigment-selective treatment and significantly reduced risk of complications.


1.2 Standard Definition of LFHSS

LFHSS must meet all of the following technical criteria:

ParametroStandard Requirement
Dimensione spot≥ 6 mm
Fluence≤ 3 J/cm²
Treatment EndpointMild warming or slight erythema

Wavelength Characteristics

  • 1064 nm → deeper penetration; targets dermal pigment (melasma, Hori’s nevus, PIH)
  • 755 nm → higher melanin absorption; ideal for epidermal pigment (freckles, epidermal melasma)

Durata dell'impulso

  • Picosecond → photomechanical pigment fragmentation + skin rejuvenation
  • Nanosecond → epidermal/dermal modulation and skin conditioning

2.1 Pigmentary Disorders

(1) Melasma – 1064 nm Nanosecond Laser as Standard of Care

Recommended Parameters

  • Dimensione del punto: 6–8 mm
  • Fluence: 1–3 J/cm²
  • Frequenza: 5–10 Hz
  • Interval: every 2–4 weeks
  • Total sessions: ≤ 15 sessions
    (Exceeding 15 sessions increases risk of mottled hypopigmentation.)

Meccanismo:
LFHSS applies “subcellular selective photothermolysis”—breaking melanosomes while preserving melanocyte viability, thereby reducing PIH and rebound pigmentation.


Figure-1.-Before-and-after-comparison-of-LFHSS-1064-nm-nanosecond-laser-treatment-for-melasma-a-before-treatment-b-after-treatment.png
Figure 1. Before-and-after comparison of LFHSS 1064 nm nanosecond laser treatment for melasma (a before treatment, b after treatment).

(2) Hori’s Nevus / Dermal Melanocytosis

First choice:
755 nm picosecond laser
→ stronger photomechanical fragmentation
→ lower risk of PIH

If using a 1064 nm nanosecond device:

  • Dimensione del punto: 6–8 mm
  • Fluence: 1–3 J/cm²
  • Frequenza: 5–10 Hz
  • Interval: 2–4 settimane
Figure-2.-Before-and-after-comparison-of-LFHSS-1064-nm-laser-treatment-for-Horis-nevus-dermal-melanocytosis
vFigure 2. Before-and-after comparison of LFHSS 1064 nm laser treatment for Hori’s nevus (dermal melanocytosis).

2.2 Inflammatory & Degenerative Skin Conditions

(1) Rosacea & Steroid-Induced Dermatitis

Recommended (1064 nm nanosecond “toning mode”)

  • Dimensione del punto: 6–8 mm
  • Fluence: 0.3–1.5 J/cm²
  • Interval: 4 settimane

Mechanisms:

  • Modulates vascular reactivity
  • Reduces inflammatory cytokines
  • Accelerates barrier repair
  • Improves flushing and sensitivity

(2) Skin Rejuvenation (755 nm Picosecond + MLA Technology)

Recommended Parameters

  • Dimensione del punto: 6–8 mm
  • Fluence: 0.5–1.0 J/cm²
  • Frequenza: 5–10 Hz
  • Interval: every 4 weeks

Vantaggi:

  • Collagen neogenesis
  • Texture e affinamento dei pori
  • Fine lines reduction
  • Tempi di inattività minimi
Figure-3.-Picosecond-fractional-laser-for-facial-rejuvenation-1A-before-treatment-1B-one-month-after-three-treatment-sessions
Figure 3. Picosecond fractional laser for facial rejuvenation (1A before treatment; 1B one month after three treatment sessions).

3. Treatment Precautions

3.1 Patch Test Protocol (Mandatory Step)

  1. Start with 1 J/cm², deliver 1–2 shots, observe for 5 minutes
    • If purplish erythema or pain → decrease fluence by 0.2–0.5 J/cm²
    • If minimal reaction → increase by 0.2–0.5 J/cm² (not exceeding 3 J/cm²)
  2. During full-face treatment, ensure the skin temperature stays below 40°C after 2–3 passes.

3.2 Preventing Excess Energy Accumulation

  • Overlap rate: ≤ 10%
  • Melasma: do not exceed 15 lifetime sessions
  • Periocular & perioral areas: reduce fluence by 20%
  • Always enable device cooling
    (air cooling / contact cooling / cryogen depending on device)

4. Contraindications

4.1 High-Vascular-Density Lesions (Port-Wine Stain, Hemangioma)

1064/755 nm wavelengths have low hemoglobin absorption
LFHSS fluence is insufficient to coagulate vessels →
May worsen vascular proliferation → Contraindicated


4.2 High-Density Tattoo Pigment

LFHSS fluence cannot reach the “instantaneous pigment explosion threshold” needed for tattoo removal.

  • Leads to inadequate fragmentation
  • Requires excessive sessions
  • Increases inflammation and PIH

→ Use high-fluence Q-switched or picosecond protocols instead.


4.3 Hyperkeratotic Lesions (Seborrheic Keratosis, Warts)

LFHSS is non ablativo and relies mainly on photobiomodulation →
Cannot vaporize keratin →
May stimulate further hyperkeratosis → Contraindicated


Conclusione

LFHSS technology, based on large spot size and low fluence, provides a safer, gentler laser strategy across multiple wavelengths and pulse modes. It offers significant benefits in:

  • Pigmentary disorders
  • Inflammatory skin conditions
  • Ringiovanimento della pelle
  • Sensitive-skin management

However, clinicians should note:

  • Clear clinical consensus currently exists only for melasma
  • 15 sessions increases risk of mottled hypopigmentation
  • Evidence for rosacea and rejuvenation requires more long-term RCTs
  • Contraindications must be strictly followed

Future studies—especially multicenter randomized controlled trials—are essential to further define LFHSS treatment boundaries, optimize parameters, and elevate safety standards across medical aesthetic practice.

Altri blog correlati

Perché il laser frazionato a CO₂ aiuta la guarigione della rimozione del tatuaggio

Cosa sono i laser Q-switch e YAG per la cura della pelle professionale?

Q-switchd ND: laser YAG per lesioni pigmentate: cura di melasma, lentiggini e marchi di nascita

Quanto è efficace il laser ND: YAG a commutazione Q per il trattamento del melasma?

Laser Pico Q-Switched: la guida completa al meccanismo e alla gamma di trattamenti & Note sulla sicurezza

Laser Pico vs Laser CO₂: qual è il migliore per la rimozione dei tatuaggi?

CO₂ frazionata + PicoWay: una combinazione pratica e redditizia per una ristrutturazione più profonda & controllo del pigmento

Guida clinica per il laser Pico in base alle reazioni degli endpoint cutanei: ottimizzare Pico & Prestazioni del laser al nanosecondo

Laser a commutazione Q: meccanismo, indicazioni, controindicazioni, parametri & Precauzioni

Tempo di recupero laser a q-switch: cosa aspettarsi e come accelerare la guarigione

Funzionamento della macchina portatile al picosecondo Picoway

Qual è la migliore macchina laser per la rimozione del tatuaggio professionale nel 2025?

Meraviglioso! Condividi questo articolo

Informazioni sull'autore

Ella di Mico Aes

Ella Chan

Benvenuti nel canale del mio blog, dove porto oltre 10 anni di esperienza nel settore delle macchine per la bellezza. Dalle macchine per saloni ai dispositivi di bellezza per uso domestico, ti guiderò attraverso gli ultimi progressi, fornirò informazioni affidabili e ti aiuterò a prendere decisioni informate. Unisciti a me in questo viaggio di trasformazione per sbloccare il tuo vero potenziale di bellezza con il potere della tecnologia.

Visualizza più prodotti

A proposito di Mico Aes

mico aes logo-3

Mico Aes è un produttore di macchine di bellezza professionali da oltre 15 anni in Cina, disponiamo di tutti i tipi di macchine per med spa, macchine per la depilazione laser e IPL, macchine hifu, macchine per emsculpting, macchine per criolipolisi, macchine laser pico, macchine rf, macchine per cavitazione , macchine idrofacciali e dispositivi per terapia della luce a led e alcuni dispositivi di bellezza per uso personale. Maggiori dettagli, O contattaci.

Carrello
Torna in alto