RF maskine
- ✓ Direkte fra fabrikken
- ✓ Inspektion før forsendelse & Afprøvning
- ✓ Operatøruddannelse & Protokoller
- ✓ 1 års garanti + Livsvarig fjernsupport
- ✓ Reservedele & Reparationssupport
- ✓ OEM / Distributør Support
Udforske professional radiofrequency machines for face, body, RF microneedling, and specialized applications. Compare monopolar, bipolar, multipolar, fractional, 448 kHz, non-contact, and combination RF systems by electrode design, energy control, applicators, cooling, and workflow.
Monopolære RF-systemer
Compare single-active-electrode platforms that typically use a return pad and are available with face- and body-specific applicators. View Monopolar RF Machines →RF Microneedling Systemer
Explore fractional systems that deliver RF energy through needle electrodes at adjustable, model-specific depths. View RF Microneedling Machines →Specialized Intimate RF
Browse dedicated internal and external RF systems that require specialized applicators, protocols, training, and regulatory review. View Vaginal RF Machines →Main Categories of RF Beauty Machines
RF systems are primarily categorized by how electrical current travels between their electrodes. This configuration influences the energy field and treatment workflow, but actual tissue heating and depth also depend on frequency, power, impedance, contact, cooling, and applicator geometry.Monopolær RF
Uses one active treatment electrode and a separate return pad or grounding component to complete the electrical circuit.Bipolar RF
Places two electrodes within the same handpiece, with current flowing through tissue between the paired contact points.Multipolær RF
Uses three or more electrodes in an alternating configuration to distribute energy across multiple paths within the treatment area.RF -mikronedling
Uses penetrating needle electrodes to deliver fractional RF energy at selected depths according to the cartridge and device settings.INDIBA-Type 448 kHz RF
Uses a specified 448 kHz RF frequency and may include capacitive and resistive energy-transfer modes, depending on the model and applicators.Non-Contact RF
Delivers RF energy without continuous manual movement of a contact handpiece and is designed for selected hands-free body-treatment workflows.Hybrid RF Platforms
Combine RF with ultrasound, vacuum, cooling, microneedling, or other technologies in one treatment platform.RF Technology Comparison
| RF type | Electrical Configuration | Typisk positionering | Nøglepunkter at sammenligne |
|---|---|---|---|
| Monopolær RF | One active electrode with a separate return pad | Face or body treatment using model-specific tips | Grounding pad, tip sizes, pulse delivery, cooling, temperature monitoring, and consumable shots |
| Bipolar RF | Two electrodes located within one applicator | Localized face or body treatment areas | Electrode spacing, frequency, contact area, energy levels, temperature feedback, and coupling requirements |
| Multipolær RF | Three or more alternating electrodes | Multi-area treatments with applicator-dependent coverage | Electrode arrangement, switching pattern, applicator sizes, temperature control, and movement technique |
| RF -mikronedling | RF delivered through penetrating needle electrodes | Fractional professional skin procedures | Monopolar or bipolar mode, insulated needles, depth, pulse duration, cartridges, sterility, and training |
| INDIBA-Type 448 kHz RF | Continuous RF at a specified 448 kHz frequency | Capacitive or resistive energy-transfer workflows | Frequency, electrode modes, return plate, applicators, power control, temperature monitoring, and intended use |
| Non-Contact RF | RF field delivered without a moving contact applicator | Selected hands-free body-contouring workflows | Treatment-zone size, positioning, distance control, energy distribution, temperature monitoring, and supported areas |
| Hybrid RF | RF combined with one or more additional technologies | Practices offering several treatment approaches | Specifications of every module, simultaneous operation, handpiece changeover, maintenance, and training |
Electrode configuration alone does not determine treatment depth, safety, comfort, or results. Compare the complete device specification and intended use rather than relying only on labels such as monopolar, bipolar, or multipolar.
RF maskine
Viser 13–24 of 39 resultsSorteret efter popularitet
-
XERF-stil dobbelt frekvens 6,78 MHz + 2 MHz monopolær RF-maskine
$8.999,00Oprindelig pris var: $8.999,00.$6.999,00Nuværende pris er: $6.999,00. -
GoldCore håndholdt guld RF Microneedling Pro – 4-i-1 bipolært RF hudforyngelsessystem
$899,00Oprindelig pris var: $ 899,00.$799,00Nuværende pris er: 799,00 USD. -
Gelpuder til EMS -ansigtsmaskine
$1.200,00 -
448KHz Indiba Activ Therapy Radiofrekvenssystem til smertelindring og fedtfjernelse 300–400W effekt
$899,00Oprindelig pris var: $ 899,00.$869,00Nuværende pris er: 869,00 USD. -
MVS Hifu MPT 3.0 MASKINE MED EMS RF
$5.099,00Oprindelig pris var: $ 5.099,00.$4.899,00Nuværende pris er: $ 4.899,00. -
Bærbar termisk fraktionel hud-resurfacing termo-mekanisk maskine
$2.999,00 – $3.399,00Prisklasse: $ 2.999,00 ved $ 3.399,00 -
9 i 1 (10 i 1) kropskontur-slankemaskine med 80K ultralydslipo-kavitation
$2.299,00 – $2.499,00Prisklasse: 2.299,00 $ ved 2.499,00 $
RF Machines by Treatment Area
Professional practices may organize RF equipment by facial, body, fractional, or intimate applications. A system designed for one area should not automatically be assumed appropriate for another.Facial RF
Facial systems generally use smaller applicators and controls intended for localized areas such as the face, neck, or jawline.Body RF
Body-focused systems may use larger applicators, hands-free panels, vacuum, or combination technologies for broader treatment areas.Fractional RF
Fractional systems create separated zones of RF delivery using microneedles, pins, or electrode arrays, depending on the device.Intimate RF
Intimate systems use specialized internal or external applicators and require dedicated professional training, protocols, and regulatory review.RF vs HIFU
Radiofrekvens
RF creates heat through electrical resistance and may be delivered through contact electrodes, needle electrodes, or non-contact applicators. The energy pattern depends on the electrode configuration and settings. Explore RF Machines →HIFU
HIFU uses focused acoustic energy delivered at cartridge-defined depths. Its delivery method, applicators, parameters, and treatment workflow differ from RF systems. Explore HIFU Machines →RF and HIFU are not interchangeable. Some practices offer both, but each device must be assessed according to its authorized uses, operator requirements, and client suitability.
What to Compare Before Buying an RF Machine
Electrode Configuration
Confirm whether the system is monopolar, bipolar, multipolar, fractional, non-contact, or capable of several RF modes.Energy and Frequency
Review operating frequency, power adjustment, pulse controls, energy stability, impedance feedback, and available presets.Temperature Management
Compare temperature sensors, automatic limits, cooling, contact monitoring, real-time display, and emergency controls.Applicators and Treatment Areas
Check handpiece sizes, tip options, face and body compatibility, supported areas, and whether return pads are required.Consumables and Accessories
Identify grounding pads, treatment tips, cartridges, coupling products, replacement handpieces, and their ongoing costs.Arbejdsgang og kapacitet
Assess setup, treatment time, operator involvement, cooling capacity, changeover, cleaning, and expected daily workload.Uddannelse og dokumentation
Confirm access to model-specific operation guidance, safety resources, maintenance instructions, and treatment documentation.Garanti og service
Review warranty coverage, spare-parts availability, remote troubleshooting, software support, and repair procedures.Regulatory Requirements
Verify the model, manufacturer, labeling, intended uses, certifications, and market-specific authorization before purchase.Professionel brug og sikkerhedshensyn
RF equipment generates heat in tissue and should be operated by appropriately qualified professionals following the instructions for the exact device. Client screening, applicator selection, contact, energy settings, movement technique, and temperature control can all affect safety. Special consideration may be required for clients with active electronic implants, implanted metal, metal-containing tattoos in the treatment area, relevant medical conditions, previous procedures, or other manufacturer-listed contraindications. Potential complications vary by technology and may include discomfort, redness, swelling, blistering, burns, pigment changes, nodules, scars, unwanted fat loss, or nerve injury. RF microneedling also introduces skin-penetration and infection-control considerations.Do not describe RF treatment as completely safe, painless, suitable for every client, or requiring no recovery. Results and temporary responses vary by device, parameters, treatment area, operator, and individual factors.
Training, Warranty, and Technical Support
Operatøruddannelse
Review available setup, operation, applicator, parameter, cleaning, maintenance, and safety resources before professional use. Udforsk træningsressourcer →Garantioplysninger
Confirm the warranty period, covered components, exclusions, service process, and responsibilities for parts and shipping. Gennemgå garantioplysninger →Teknisk support
Check troubleshooting procedures, remote assistance, replacement components, software support, and repair options. Se teknisk support →Need help comparing RF systems? Kontakt Mico AES with your planned applications, preferred electrode configuration, target areas, expected workload, budget, and destination market.























