Máy tạo sóng mát

  • ✓ Nhà máy trực tiếp
  • ✓ Kiểm tra trước khi giao hàng & Kiểm tra
  • ✓ Đào tạo người vận hành & Giao thức
  • ✓ Bảo hành 1 năm + Hỗ trợ từ xa trọn đời
  • ✓ Phụ tùng thay thế & Hỗ trợ sửa chữa
  • ✓ Hỗ trợ OEM/Nhà phân phối

Professional Cool Wave Body Contouring Machines
Compare professional 2.45GHz microwave body contouring systems designed for localized fat-management, skin-firming and cellulite-appearance treatment programs. Choose from standard Cool Wave machines, three-applicator Pro systems and combined microwave plus electromagnetic muscle stimulation platforms.
Mico Aes supplies clinics, med spas, beauty centers and equipment distributors with MOQ 1, pre-shipment inspection, operator training, a one-year main-unit warranty, eligible handpiece coverage and 24/7 remote technical support.

View Cool Wave Machines

Hiển thị tất cả 3 kết quảĐã sắp xếp theo mức độ phổ biến

Professional 2.45GHz Microwave Body Contouring Systems

Compare Cool Wave Machines for Your Clinic or Beauty Business

Cool Wave machines use controlled 2.45GHz microwave energy together with contact cooling for professional body-contouring applications. Depending on the selected model, the system may support localized fat-management, skin-firming, cellulite-appearance and combined muscle-conditioning programs. This category includes a standard Cool Wave platform, an upgraded three-applicator Cool Wave Pro system and a multifunction model combining microwave technology with electromagnetic muscle stimulation. Compare the actual applicators, cooling design, operating modes, power requirements and included accessories before choosing a machine.

How 2.45GHz Cool Wave Technology Works

Controlled Microwave Energy

The machine delivers controlled 2.45GHz microwave energy through a dedicated applicator. The energy produces dielectric heating within the selected treatment area according to the machine settings and operating protocol.

Integrated Contact Cooling

The applicator cooling system helps manage the skin-contact temperature during energy delivery. Cooling specifications, temperature ranges and operating controls vary by model and should be confirmed on the individual product page.

Model-Specific Treatment Modes

Available modes may include localized fat-management, skin-firming, cellulite-appearance and lifting programs. The combination model also provides electromagnetic muscle stimulation through separate applicators.

Professional Parameter Control

Operators should select energy, cooling, treatment time and applicator type according to the device manual, client assessment, treatment area and applicable local requirements.

Cool Wave is a product-category name used for these microwave-based systems. It should not be interpreted as proof that every model has identical output, cooling performance, applicators or intended uses.

Core Professional Applications

Localized Body Contouring

Supports professional protocols designed for selected localized areas where clients are seeking improved body-contour appearance. It is not a substitute for medical weight-loss treatment.

Skin-Firming Programs

Controlled thermal protocols may be incorporated into professional skin-firming and body-care services, subject to the selected model and its documented intended use.

Cellulite-Appearance Care

Selected applicators and operating modes may support programs intended to improve the visible appearance of uneven skin texture and cellulite-prone areas.

Muscle Conditioning

The combination system adds separate electromagnetic applicators for involuntary muscle-contraction programs. This function is not included with every Cool Wave machine.

Cool Wave Machine Model Comparison

Model Type Công nghệ cốt lõi Cấu hình ứng dụng Primary Buying Consideration
Standard Cool Wave 2.45GHz microwave with contact cooling Confirm current configuration before ordering Dedicated microwave body-contouring workflow
Cool Wave Pro 2.45GHz microwave with contact cooling Small-area, shallow and deep applicators Greater flexibility across different areas and treatment goals
Combination System 2.45GHz microwave plus electromagnetic muscle stimulation Two microwave and two electromagnetic applicators Body-contouring and muscle-conditioning services in one platform

Specifications may change between production versions. Request the current specification sheet, applicator list, voltage configuration and quotation for the exact model before purchase.

Cool Wave vs. Other Body Contouring Technologies

Công nghệ Energy Method Typical Professional Focus Người mua nên so sánh những gì
Cool Wave Microwave Controlled 2.45GHz microwave energy Localized contouring, firming and cellulite-appearance programs Applicators, cooling, output controls and operating modes
Tần số vô tuyến RF electrical energy at a model-specific frequency Thermal skin-firming and body-care protocols Frequency, electrode design, cooling and measured output
Cavitic siêu âm Siêu âm tần số thấp Non-invasive body-contouring programs Frequency, handpiece design, output and combination functions
Cryolipolysis Làm mát có kiểm soát Localized fat-management programs Applicator sizes, cooling control, membranes and consumables
Kích thích điện từ Electromagnetic field Muscle-conditioning programs Applicator quantity, field intensity, frequency and cooling
Microwave and RF systems should not be compared only as “deep” versus “shallow.” Their performance depends on frequency, applicator design, output, cooling, operating parameters and treatment protocol. Ask for specifications for the exact model rather than relying on technology names alone.

Compare Available Cool Wave Machines

Professional Buying Guide

How to Choose a Cool Wave Body Contouring Machine

Begin with the services you plan to offer. A dedicated microwave system may suit clinics focused on thermal body-contouring protocols, while the three-applicator Pro model provides more flexibility for different areas. The combination system is intended for businesses that also want electromagnetic muscle-conditioning services.

1. Compare Applicators

Check the number, shape and intended use of each applicator. Confirm whether the machine includes dedicated small-area, shallow-treatment, deep-treatment or electromagnetic applicators.

2. Verify Energy Controls

Request the operating frequency, output range, adjustable levels, treatment timers and available modes for the exact production model.

3. Review the Cooling System

Confirm the cooling method, adjustable temperature range, water-circulation requirements and safeguards used to manage applicator contact temperature.

4. Check Electrical Requirements

Verify total rated power, voltage, plug configuration and installation requirements. Do not rely only on the output figure shown for an individual function.

5. Calculate Operating Costs

Ask about required consumables, coolant or water maintenance, applicator servicing, spare parts, shipping and any accessories not included in the standard package.

6. Confirm Documents and Support

Request the current manual, packing list, available compliance documents, training materials, warranty terms and after-sales process for the model and destination market.

Choosing Between the Three Available Configurations

Choose the Standard Model If…

You need a dedicated 2.45GHz microwave platform and prefer a simpler treatment menu without a separate muscle-stimulation function.

Choose Cool Wave Pro If…

You want separate applicators for smaller areas, shallow body treatments and deeper body-contouring protocols within one microwave platform.

Choose the Combination Model If…

You want to combine microwave body-contouring treatments with electromagnetic muscle-conditioning services and have sufficient space and power capacity for a multifunction platform.

Treatment Areas and Protocol Planning

Depending on applicator design and the model’s documented intended use, Cool Wave systems may be considered for professional protocols involving the abdomen, waist, flanks, thighs, buttocks, upper arms, back and other localized areas. Smaller treatment zones should only be treated with a suitable applicator and documented protocol. Treatment time, energy level, cooling setting, session interval and total number of sessions should be determined individually rather than presented as a universal schedule.

Results vary according to the machine configuration, operator technique, selected parameters, treatment area and individual client factors. Avoid promising a fixed percentage of fat reduction or a guaranteed result after one session.

Safety and Operator Responsibilities

Trước khi điều trị

  • Review the device manual and intended-use statement.
  • Complete client screening and informed consent.
  • Check contraindications, medical history and implanted devices.
  • Inspect the applicator, cables, cooling circuit and emergency controls.
  • Confirm that the selected settings are appropriate for the treatment area.

Trong và sau khi điều trị

  • Monitor skin response and client feedback throughout the session.
  • Maintain full applicator contact where required by the protocol.
  • Stop treatment if unexpected pain, overheating or an adverse response occurs.
  • Provide model-specific aftercare rather than promising zero downtime.
  • Document parameters, treatment area and observed response.
Professional operation, contraindication screening and regulatory requirements vary by country. Buyers are responsible for confirming whether the selected equipment and proposed services are permitted in their market.

What to Confirm Before Ordering

Cấu hình máy

Model number, applicator quantity, microwave functions, electromagnetic functions, cooling method and included accessories.

Electrical Specifications

Rated power, input voltage, frequency, plug standard and any installation or circuit requirements.

Shipping Package

Machine dimensions, net weight, gross weight, flight-case dimensions, packing list and available shipping methods.

Tài liệu

Operator manual, treatment guidance, maintenance instructions and available model-specific regulatory documentation.

Phạm vi bảo hành

One-year main-unit warranty and six-month coverage for eligible handpieces, subject to the written warranty terms and exclusions.

Hỗ trợ sau bán hàng

Basic operator training, 24/7 remote technical support, troubleshooting assistance and spare-parts or repair support.

Manufacturing, Documentation and After-Sales Support

Thông tin nhà máy

Learn about Mico Aes production, machine inspection and equipment supply capabilities.

OEM and ODM Service

Discuss model-dependent branding, interface language, machine color, packaging and accessory customization.

Thông tin bảo hành

Read the applicable warranty coverage, exclusions and service process before ordering.

Câu hỏi thường gặp

What is a Cool Wave machine?
A Cool Wave machine is a professional body-contouring platform that uses controlled 2.45GHz microwave energy and applicator cooling. Available configurations include dedicated microwave systems, three-applicator Pro models and combined microwave plus electromagnetic muscle-stimulation systems.
What is the difference between the standard and Pro models?
The Pro model is positioned as an upgraded system with three applicators intended for small, shallow and deeper treatment applications. The standard model provides a more focused microwave body-contouring configuration. Confirm the current specifications for each production version before ordering.
Does every Cool Wave machine include muscle stimulation?
No. Electromagnetic muscle stimulation is included only on the combination model. The standard Cool Wave and Cool Wave Pro machines are primarily microwave-based systems.
How is Cool Wave different from radiofrequency?
Cool Wave systems in this category use 2.45GHz microwave energy, while RF machines use electrical radiofrequency energy at their specified operating frequency. Treatment behavior depends on applicator design, power delivery, cooling and protocol, so buyers should compare documented specifications rather than relying only on general depth claims.
How many sessions does a client need?
There is no universal session number. Treatment planning depends on the selected machine, operating protocol, target area, client assessment and response. Operators should follow the current device manual and applicable professional guidance.
Can Cool Wave machines be used on the face?
Only a model equipped with an appropriate small-area applicator and documented protocol should be considered for smaller treatment areas. Confirm the intended use of the exact Cool Wave Pro applicator before offering facial or under-chin treatments.
Is cooling included?
The listed systems include cooling intended to manage the skin-contact temperature during energy delivery. Cooling ranges, circulation methods and controls vary by model and should be verified in the current specification sheet.
What voltage options are available?
Selected models are available in 110V or 220V configurations. Confirm the voltage, plug type, frequency and electrical requirements for your country before production and shipment.
What warranty and technical support are included?
Mico Aes provides a one-year warranty for the main unit and six-month coverage for eligible handpieces, subject to the written warranty terms. Basic operator training, 24/7 remote technical support and spare-parts assistance are also available.
Can I order one Cool Wave machine?
Yes. The standard minimum order quantity is one unit. OEM, ODM and distributor requirements may have different minimum quantities depending on the requested customization.

Request a Current Cool Wave Machine Quotation

Tell us which services you plan to offer, your preferred machine configuration, destination country and voltage requirement. We can help you compare the standard Cool Wave machine, the three-applicator Cool Wave Pro and the microwave plus electromagnetic muscle-stimulation system. Before confirming an order, request the current specification sheet, applicator list, packing details, available documentation, warranty terms and shipping quotation for the exact model.

Get Cool Wave Machine Recommendations and Pricing

Giỏ hàng
Lên đầu trang