São: Lasers Yag 2940nm
- ✓ Direto da fábrica
- ✓ Inspeção Pré-Embarque & Teste
- ✓ Treinamento de Operadores & Protocolos
- ✓ Garantia de 1 ano + suporte remoto vitalício
- ✓ Peças de reposição & Suporte de reparo
- ✓ Suporte OEM/Distribuidor
Professional 2940nm Er:YAG Laser Machines
Explore professional 2940nm Er:YAG laser systems for precise skin resurfacing, fractional ablation, scar-focused treatments, and compatible dental procedures. Compare treatment modes, pulse controls, spot sizes, scanning systems, cooling, handpieces, and clinical configurations.
Apenas um resultado
Professional Ablative Laser Equipment
2940nm Er:YAG Laser Machines
A 2940nm Er:YAG laser is an ablative infrared laser with strong absorption in water. It removes controlled microscopic layers of water-containing tissue, allowing precise resurfacing with comparatively limited residual thermal spread. Depending on the machine configuration, Er:YAG systems may offer full-field ablation, fractional resurfacing, micro-peel, long-pulse coagulation, or dental treatment modes. The intended applications must be confirmed for the exact model.Full-Field & Micro-Peel Modes
Remove controlled surface layers for selected texture, fine-line, photodamage, and superficial resurfacing protocols.Scar-Focused Treatments
Fractional, ablative, or combined modes may be used in professional protocols for selected atrophic acne and surgical scars.Dental Er:YAG Systems
Model-specific dental platforms use specialized tips and water-spray systems for compatible hard- and soft-tissue procedures.How 2940nm Er:YAG Laser Treatment Works
Treatment depth and thermal effect depend on pulse energy, pulse duration, spot size, treatment density, number of passes, scanning pattern, and cooling or water-spray configuration.| Modo de tratamento | Fornecimento de energia | Selected Applications | What to Compare |
|---|---|---|---|
| Fractional Ablative | Creates separated microscopic ablation columns. | Selected acne scars, uneven texture, fine lines, and skin resurfacing. | Fractional density, depth, spot pattern, pulse energy, and scanner control. |
| Full-Field Ablative | Removes a controlled continuous surface layer. | Selected superficial resurfacing and lesion-focused procedures. | Ablation depth, pulse duration, spot size, number of passes, and plume management. |
| Micro-Peel | Uses comparatively superficial ablation settings. | Selected rough texture, photodamage, and surface-renewal workflows. | Depth control, coverage, pulse consistency, comfort measures, and aftercare. |
| Dental Mode | Uses specialized tips, pulse settings, and water spray. | Compatible hard- or soft-tissue dental applications specified by the manufacturer. | Dental indication, tip selection, water control, handpiece, suction, and operator qualifications. |
Importante: A 2940nm wavelength does not mean every Er:YAG machine supports both dermatological and dental applications. Confirm the intended use, treatment modes, handpieces, tips, software, documentation, and regulatory status of the exact model.
Guia de compra profissional
How to Choose a 2940nm Er:YAG Laser Machine
Choose an Er:YAG system according to the intended treatment category, ablation controls, pulse modes, scanner design, handpieces, cooling, water delivery, operator training, and destination-market requirements.Confirm the Intended Application
Determine whether the machine is designed for dermatology, aesthetic resurfacing, scar-focused treatments, dentistry, or a documented combination of applications.Compare Treatment Modes
Review full-field, fractional, micro-peel, short-pulse, long-pulse, and coagulation modes available on the exact system.Review Ablation Controls
Compare pulse energy, pulse duration, spot size, repetition rate, fractional density, treatment depth, scanning patterns, and number of passes.Check Handpieces & Pontas
Confirm scanner handpieces, treatment windows, dental tips, consumables, sterilization requirements, replacement availability, and compatibility.Plan Safety & Fluxo de trabalho da clínica
Review eye protection, plume evacuation, cooling or water spray, smoke management, room requirements, cleaning, and infection-control procedures.Verify Training & Documentação
Request technical specifications, the user manual, safety information, treatment guidance, warranty terms, service support, and destination-market documents.Er:YAG vs CO₂ Resurfacing
Both technologies can be used for ablative resurfacing. Er:YAG energy is strongly absorbed by water and generally creates less residual thermal injury, while CO₂ systems may provide a broader coagulative effect. Neither technology is universally better. The appropriate choice depends on treatment depth, skin condition, scar type, recovery expectations, operator experience, and the exact device settings.Experiência de tratamento & Segurança
Ablative treatment can cause redness, swelling, sensitivity, crusting, oozing, infection, pigment changes, or scarring. The intensity and recovery period vary with treatment mode, depth, area, skin type, and individual healing response. Client assessment should review skin type, active infection, recent sun exposure, medication, previous procedures, wound-healing history, and susceptibility to post-inflammatory pigmentation.Importante: Avoid guaranteeing faster healing, minimal discomfort, permanent scar removal, or suitability for every skin type. Results and recovery depend on the machine, settings, treatment protocol, operator, and client.