• تدريب مجاني + بروتوكولات & مقاطع الفيديو
  • إمدادات الطاقة الطبية في Meanwell
  • تخصيص الشعار مجانا
  • 12 شهرا ضمان + خدمة الصيانة مدى الحياة يدعم
  • 7/24 اتصال خدمة
  • شحن مجاني في جميع أنحاء العالم

حاسبة العائد على الاستثمار



XERF Dual Frequency 6.78 MHz + 2 MHz Monopolar RF Machine

  • Short Description
  • XERF is a professional dual-frequency monopolar RF system combining 6.78 MHz and 2 MHz for multi-depth skin tightening. With Shallow, Middle and Deep treatment modes, it delivers controlled thermal energy from the dermis toward deeper supporting tissue.
  • الميزات الرئيسية
  • Dual-frequency monopolar RF: 6.78 MHz + 2 MHz
  • Shallow, Middle and Deep treatment modes
  • 10 adjustable energy levels
  • Up to 150 W RF output
  • Real-time impedance synchronization
  • Surface-temperature and energy monitoring
  • Wave Fit multi-pulse energy delivery
  • Three-level ICD cooling
  • Four Effector sizes for precise and large-area treatment
  • Suitable for the face, jawline, submental area and neck
  • Non-invasive treatment with minimal downtime

ًالشحن مجانا + تدريب مجاني

$8,999.00

دولارات الولايات المتحدة ($) - USD
  • دولارات الولايات المتحدة ($) - USD
  • يورو (€) - EUR
  • جنيه إسترليني (£) - GBP
- +
وصف

XERF Dual-Frequency Monopolar RF System

Multi-Depth RF Skin Tightening with 6.78 MHz and 2 MHz

XERF is a non-invasive monopolar radiofrequency system designed to deliver controlled thermal energy across multiple tissue depths.

من خلال الجمع 6.78 MHz and 2 MHz RF frequencies, XERF provides three selectable thermal diffusion modes—Shallow, Middle, and Deep—allowing practitioners to adapt treatment according to tissue thickness, anatomical area, and individual skin characteristics.

With real-time impedance synchronization, adjustable RF output, surface-temperature monitoring, Wave Fit Pulse technology, and three-level ICD cooling, XERF supports precise energy delivery while helping improve treatment comfort and epidermal protection.

XERF (10) (1)

الميزات الرئيسية

  • Dual-frequency monopolar RF: 6.78 MHz and 2 MHz
  • Shallow, Middle, and Deep treatment modes
  • Ten adjustable RF output levels
  • Real-time impedance synchronization
  • Wave Fit multi-pulse energy delivery
  • Three-level ICD cooling
  • Surface-temperature monitoring
  • Four Effector sizes
  • العلاج غير الغازية
  • Minimal or no significant downtime

Why Skin Becomes Loose

Skin firmness and elasticity depend on an organized extracellular matrix containing collagen, elastin, fibroblasts, and other structural components.

With age and environmental exposure, the skin gradually experiences:

  • Reduced Type I and Type III collagen
  • Fragmentation of existing collagen fibres
  • Decreased elastin organization
  • Lower fibroblast activity
  • Reduced extracellular matrix renewal
  • Changes in subcutaneous tissue support
  • Progressive weakening of facial contours

These changes can lead to:

  • الخطوط الدقيقة والتجاعيد
  • Reduced skin elasticity
  • الخدين المتدعي
  • Loss of jawline definition
  • Loose skin around the face and neck
  • Changes in facial volume and tissue support

Effective skin-tightening treatments should therefore address more than the visible surface. Controlled energy must be delivered into the appropriate tissue depths to initiate collagen contraction and longer-term tissue remodelling.


Why Monopolar RF?

Monopolar radiofrequency delivers electrical energy from the treatment electrode through the tissue toward a return electrode.

As RF energy passes through tissue, electrical resistance converts the energy into controlled heat.

The RF Tissue-Remodelling Process

Monopolar RF Energy

Electrical Resistance within Tissue

Controlled Thermal Energy

Immediate Collagen Fibre Contraction

تنشيط الخلايا الليفية

Collagen and Elastin Remodelling

Progressive Improvement in Skin Firmness

The controlled thermal response can cause existing collagen fibres to contract while stimulating the biological processes involved in collagen renewal and reorganization.

Some patients may notice an initial feeling of firmness after treatment. Further improvements may develop gradually as collagen remodelling continues over the following weeks and months.

Results vary according to individual skin condition, treatment area, selected parameters, number of shots, and treatment plan.


Why Dual-Frequency RF?

Traditional monopolar RF platforms commonly operate at a single frequency, creating a relatively fixed thermal profile.

However, facial and body anatomy is not uniform. The forehead, cheeks, jawline, neck, abdomen, and thighs differ in:

  • Skin thickness
  • Connective tissue density
  • Subcutaneous fat distribution
  • Surface contours
  • Electrical impedance
  • Required treatment depth

XERF combines 6.78 MHz and 2 MHz monopolar RF to provide greater flexibility in the distribution of thermal energy.

The practitioner can select Shallow, Middle, or Deep mode based on the treatment area and desired degree of thermal diffusion.

XERF (15)
XERF (15)

Why 6.78 MHz?

The 6.78 MHz frequency is used in both Shallow and Middle modes.

By changing the system parameters, XERF can use the same frequency to create different degrees of thermal diffusion.

Shallow Mode

Shallow mode applies 6.78 MHz using parameters designed to produce the lowest degree of thermal diffusion among the three modes.

It may be selected for:

  • الجبين
  • Periorbital region
  • Areas around the mouth
  • Narrow facial areas
  • Relatively thin tissue

Treatment objectives may include:

  • Supporting dermal collagen remodelling
  • Improving the appearance of fine lines
  • Enhancing superficial skin firmness
  • Refining skin texture

Middle Mode

Middle mode also applies 6.78 MHz but uses parameters designed to create moderate thermal diffusion.

It may be selected for:

  • الخدين
  • Lower face
  • رقبة
  • Areas with moderate tissue thickness
  • General facial tightening

Treatment objectives may include:

  • Improving skin elasticity
  • Supporting facial contour definition
  • Addressing mild to moderate skin laxity
  • Creating more comprehensive dermal heating

Why Add 2 MHz?

Lower-frequency RF can create a broader and deeper thermal field.

In XERF Deep mode, 6.78 MHz and 2 MHz are delivered sequentially, producing the deepest thermal diffusion of the three selectable modes.

Deep Mode

Deep mode may be selected for:

  • Lower face
  • الفك
  • Submental area
  • Areas with thicker subcutaneous tissue
  • Deeper structural tightening objectives

Official histological research cited by Lutronic reported collagen changes extending from the dermis through deeper subcutaneous tissue toward the fascial or SMAS region following combined 6.78 MHz and 2 MHz RF application.

The treatment objective is not simply to heat a single layer, but to create a controlled multi-depth thermal response according to the patient’s anatomy.


Three Depths, One Personalized Treatment

XERF allows the practitioner to combine three thermal diffusion modes within one treatment plan.

Treatment mode تردد RF Thermal diffusion Typical treatment consideration
أجوف 6.78 ميغاهيرتز Lowest thermal diffusion Thin, narrow or delicate areas
Middle 6.78 ميغاهيرتز Moderate thermal diffusion General facial and neck treatment
عميق 6.78 MHz followed by 2 MHz Deepest thermal diffusion Thicker tissue and deeper structural support

The appropriate mode should be selected by a trained practitioner following an assessment of:

  • منطقة العلاج
  • Tissue thickness
  • تراخي الجلد
  • Patient comfort
  • Clinical objective
  • Previous treatments
  • Relevant medical history

Wave Fit Pulse Technology

Controlled Energy Delivery with Coordinated Cooling

The effectiveness of monopolar RF depends not only on peak energy, but also on how that energy is distributed and maintained within the tissue.

Traditional fixed-pulse systems may deliver energy through a smaller number of concentrated pulses, potentially producing a rapid increase in temperature and greater discomfort.

XERF’s Wave Fit Pulse technology distributes RF energy across multiple controlled sub-pulses. Depending on the selected treatment setting, energy may be divided into up to 12 pulses.

ICD cooling is coordinated with the pulse sequence to support:

  • A more gradual temperature increase
  • Controlled thermal accumulation
  • Improved epidermal protection
  • More stable energy delivery
  • Greater treatment comfort

The system adapts pulse delivery according to the selected RF energy and treatment parameters, helping maintain a balance between heating and cooling.


Three-Level ICD Cooling

XERF incorporates an Integrated Cryogen Delivery cooling system at the treatment tip.

The ICD system uses controlled refrigerant-gas delivery to cool the treatment surface and help protect the epidermis during RF application.

Practitioners can select three ICD cooling levels:

  • ICD Level 1
  • ICD Level 2
  • ICD Level 3

The cooling level can be adjusted according to:

  • Effector type
  • Selected depth
  • Energy level
  • منطقة العلاج
  • Tissue response
  • Patient feedback

Additional ICD cooling may be selected when greater surface protection or improved comfort is required.

The main unit also uses an internal air-cooling system. The internal system cooling and the ICD treatment-tip cooling are separate functions.


Real-Time Impedance Synchronization

Electrical impedance differs between patients and can also vary across anatomical regions.

Before RF energy is delivered, XERF performs an impedance synchronization process by placing the Effector in contact with the treatment area.

The system evaluates the impedance of the treatment area and synchronizes RF delivery accordingly.

This supports:

  • More consistent RF energy transmission
  • Area-specific treatment settings
  • Personalized energy delivery
  • Improved treatment reproducibility
  • Detection of unsuitable electrode contact

If impedance synchronization is unsuccessful, the system returns to standby and requires the process to be repeated before RF output can continue.


Surface-Temperature and Energy Monitoring

After each RF shot, the practitioner can review important treatment information on the graphical user interface and handpiece display.

Displayed treatment data include:

  • Tip-surface temperature
  • Energy delivered in a single pulse
  • Total accumulated delivered energy
  • Shot count
  • Selected treatment depth
  • RF output level
  • ICD cooling level

This real-time information helps practitioners monitor treatment progress and make appropriate adjustments during the procedure.

Surface-temperature monitoring should be used together with continuous observation of tissue response and patient feedback.


Intuitive Treatment Interface

The 10.1-inch LCD touchscreen provides direct access to the principal treatment parameters.

Practitioners can control:

  • Shallow, Middle, or Deep mode
  • RF output Level 1–10
  • ICD cooling Level 1–3
  • Shot interval
  • Finger-switch or foot-switch activation
  • Impedance synchronization
  • Effector information
  • Delivered pulse energy
  • Accumulated energy
  • Tip-surface temperature
  • Treatment progress

The shot interval can be set to:

  • Off
  • 200 ms
  • 500 ms
  • 800 ms

When the interval is turned off, the system delivers one RF shot each time the finger switch or foot switch is activated.


Four XERF Effectors

XERF offers four disposable Effector sizes for different treatment areas and tissue contours.

Effector Contact size Maximum RF energy Available shot configurations Recommended application
Effector 05 5 × 10 mm 18.7 J 600 Narrow, thin and precise areas
Effector 10 10 × 10 mm 38.1 J 600 Small or curved facial areas
Effector 40 20 × 20 mm 140 J 600 General facial and neck coverage
Effector 60 20 × 30 mm 220 J 600 Large or thicker treatment areas

XERF (11)

Effector 05

The 5 × 10 mm Effector is designed for narrow and relatively thin treatment areas where precise contact is important.

Possible applications include:

  • Areas around the eyes
  • Areas around the mouth
  • Narrow facial contours
  • Small localized treatment zones

Effector 10

The 10 × 10 mm Effector provides controlled contact over small or curved areas.

Possible applications include:

  • Forehead contours
  • Lower face
  • Perioral region
  • Localized facial laxity

Effector 40

The 20 × 20 mm Effector is suitable for efficient general facial coverage.

Possible applications include:

  • الخدين
  • الجبين
  • الفك
  • رقبة

Effector 60

The 20 × 30 mm Effector provides a treatment area 1.5 times larger than a conventional 20 × 20 mm tip.

Its larger electrode surface allows more energy to be delivered over a broader area per shot.

Possible applications include:

  • Broad facial areas
  • Lower face
  • Submental area
  • Larger or thicker treatment zones

Treatment effectiveness should not be evaluated only by the number of shots. Effector size, pulse energy, accumulated delivered energy, treatment depth, and tissue characteristics must also be considered.


Spider-Pattern Electrode Design

The XERF Effector incorporates a distinctive spider-pattern electrode.

The distributed electrode structure is designed to support more uniform energy delivery across the contact surface and reduce excessive concentration of RF energy around the edge of the electrode.

This design supports:

  • More even RF distribution
  • Stable tissue contact
  • Reduced edge concentration
  • Controlled treatment of curved areas
  • Improved epidermal protection

The Effector must remain in proper contact with the skin throughout RF delivery.


Clinical Science

Multi-Layer Collagen Response

Official research cited by Lutronic evaluated tissue changes following the application of combined 6.78 MHz and 2 MHz RF energy.

Reported histological observations included:

  • Collagen fibre thickening
  • Collagen fibre shortening
  • Thermal changes within the dermis
  • Changes extending into deeper subcutaneous tissue
  • Collagen response near the deep fascial or SMAS region
  • Continued tissue remodelling following treatment

The research supports the concept that combining two monopolar RF frequencies can produce a deeper and more comprehensive thermal profile than a single 6.78 MHz frequency alone.

Immediate and Progressive Response

Controlled RF heating may cause an immediate contraction of existing collagen structures.

Longer-term improvement is associated with:

  • Fibroblast activation
  • Neocollagenesis
  • Collagen reorganization
  • Gradual improvement in tissue density
  • Progressive contour refinement

Improvements may continue to develop after treatment as the tissue-remodelling process progresses.

No specific result can be guaranteed, and individual responses vary.


مناطق العلاج

XERF may be used by qualified practitioners to address suitable facial and neck areas, including:

  • الجبين
  • Periorbital area
  • الخدين
  • Nasolabial region
  • Perioral area
  • Lower face
  • الفك
  • jowls
  • Submental area
  • رقبة

Depending on the local regulatory status, available Effectors and authorized indications, larger treatment areas may also be considered.

The practitioner should select the Effector, depth, output level and cooling setting according to the individual treatment area.


Treatment Objectives

XERF may support improvements in the appearance of:

  • Mild to moderate skin laxity
  • Reduced facial definition
  • Loose skin around the jawline
  • الخدين المتدعي
  • الخطوط الدقيقة
  • التجاعيد
  • Reduced skin elasticity
  • Uneven skin firmness
  • Loose skin around the neck
  • Age-related changes in facial contours

XERF is not a substitute for surgery and does not produce surgical facelift results.


Who May Be Suitable for XERF?

XERF may be considered for adults who:

  • Have mild to moderate skin laxity
  • Want non-invasive skin tightening
  • Prefer minimal or no significant downtime
  • Want to improve facial contour definition
  • Are concerned about loose skin around the face or neck
  • Want a treatment that can be adapted to different tissue depths
  • Prefer a treatment designed to reduce heat-related discomfort
  • Want to incorporate RF treatment into an ongoing skin-maintenance plan

A professional consultation is required to determine whether the treatment is appropriate.


XERF Treatment Process

1. Consultation

Before treatment, the practitioner evaluates:

  • Skin condition
  • Degree of laxity
  • Tissue thickness
  • أهداف العلاج
  • Medical history
  • Previous procedures
  • موانع
  • Expected treatment response

Clinical photographs may be taken for treatment planning and follow-up comparison.

2. Skin Preparation

The treatment area is cleaned and all relevant accessories are checked.

A patient return pad is connected and positioned according to the operator’s manual.

A thin layer of ultrasound coupling gel is applied to the treatment area. RF treatment must not be performed on dry tissue without the required coupling gel.

3. Parameter Selection

The practitioner selects:

  • Effector size
  • Shallow, Middle, or Deep mode
  • RF output level
  • ICD cooling level
  • Shot interval
  • Activation method

Parameters must be adjusted according to the anatomical area, tissue thickness and patient feedback.

4. Impedance Synchronization

The Effector is placed in contact with the treatment area and the impedance synchronization process is completed.

RF output cannot proceed until successful synchronization has been confirmed.

5. RF Energy Delivery

The practitioner maintains full contact between the Effector and the skin and activates RF delivery through the handpiece switch or foot switch.

During treatment, the practitioner monitors:

  • Patient comfort
  • Skin response
  • Surface temperature
  • Pulse energy
  • Accumulated energy
  • Electrode contact
  • Treatment symmetry

6. Post-Treatment Assessment

After treatment, the coupling gel is removed and the skin is evaluated.

Temporary warmth, redness, mild swelling or sensitivity may occur. These reactions are generally transient but should be monitored according to professional protocols.


وقت العلاج

Treatment time depends on:

  • منطقة العلاج
  • Effector size
  • Number of shots
  • Selected depth
  • Energy level
  • Individual treatment plan

A typical facial treatment may take approximately 15–30 minutes, although larger or combined treatment areas may require additional time.


Does XERF Require Anesthesia?

XERF is designed to balance RF energy delivery with coordinated ICD cooling.

Many treatments can be performed without anesthesia. Patients generally experience a warm sensation during RF delivery.

Sensitivity varies between individuals, and the practitioner should assess patient comfort throughout the procedure. The use of topical anesthesia should follow the treatment protocol and applicable clinical requirements.


Downtime and Aftercare

XERF is non-invasive and generally involves minimal or no significant downtime.

Most patients can return to normal daily activities shortly after treatment.

Possible temporary responses include:

  • احمرار
  • Warmth
  • Mild swelling
  • Tenderness
  • Temporary sensitivity

General aftercare may include:

  • Avoiding excessive heat immediately after treatment
  • Avoiding aggressive exfoliation until the skin feels normal
  • Applying gentle skincare products
  • Using broad-spectrum sunscreen
  • Following the practitioner’s individual instructions

Makeup may generally be applied once the skin is comfortable and there is no significant irritation.


XERF vs Traditional Single-Frequency Monopolar RF

ميزة Traditional single-frequency RF XERF dual-frequency RF
تردد RF Usually one fixed frequency 6.78 MHz and 2 MHz
Depth selection Relatively fixed thermal profile Shallow, Middle and Deep modes
Deep mode Limited by single-frequency delivery Sequential 6.78 MHz and 2 MHz
توصيل الطاقة May use a fixed pulse structure Wave Fit multi-pulse delivery
تبريد Depends on the platform Three-level ICD cooling
Impedance feedback Depends on the platform Impedance synchronization
Temperature monitoring Depends on the platform Tip-surface temperature display
Output adjustment Platform dependent Ten output levels
Treatment tips Limited or fixed sizes Four Effector sizes
Treatment customization More limited Area- and tissue-specific selection

The clinical performance of any RF treatment depends on the system configuration, operator technique, selected parameters and individual patient characteristics.


المواصفات الفنية

مواصفة XERF
RF type Monopolar RF
Frequencies 2 MHz and 6.78 MHz
Maximum RF output at rated load 2 MHz: 150 W @ 200 Ω
6.78 MHz: 140 W @ 200 Ω
Maximum RF output at reference load 2 MHz: 129 W @ 100 Ω
6.78 MHz: 125 W @ 100 Ω
RF output levels Level 1–10
Treatment depths Shallow / Middle / Deep
Shot intervals Off / 200 / 500 / 800 ms
ICD cooling Level 1–3
System cooling تبريد الهواء
User interface 10.1-inch LCD touchscreen
أبعاد 389 mm W × 856.4 mm L × 1604.1 mm H
وزن 47 kg
Electrical classification Class I, Type BF applied part
Electrical rating Single-phase AC 100–120 V, 50/60 Hz
استهلاك الطاقة 1 kVA
RF activation Handpiece finger switch or foot switch
Treatment electrode Disposable XERF Effector
Patient circuit Patient return pad

Specifications may vary according to the market, device version and regulatory configuration.


الأسئلة المتداولة

What is XERF?

XERF is a non-invasive monopolar RF system that combines 6.78 MHz and 2 MHz frequencies to create Shallow, Middle and Deep thermal diffusion modes.

How is XERF different from conventional monopolar RF?

Conventional platforms commonly use one RF frequency. XERF uses 6.78 MHz and 2 MHz, allowing the practitioner to select different thermal diffusion depths according to the treatment area and tissue characteristics.

How does Deep mode work?

Deep mode delivers 6.78 MHz and 2 MHz sequentially, creating the deepest thermal diffusion of the three available modes.

Does XERF reach the SMAS?

Official histological research cited by Lutronic reported collagen changes extending toward the deep fascial or SMAS region after combined 6.78 MHz and 2 MHz RF application. Actual energy distribution depends on the selected parameters and individual tissue characteristics.

Is XERF painful?

Patients generally experience warmth during treatment. Wave Fit Pulse and ICD cooling are designed to reduce discomfort and control surface heating. Individual sensitivity varies.

Is anesthesia required?

Many treatments can be performed without anesthesia. The practitioner should determine the appropriate comfort-management approach for each patient.

How long does treatment take?

A typical treatment takes approximately 15–30 minutes. Treatment time varies according to the area and number of shots.

هل هناك أي توقف؟

XERF is non-invasive and generally requires minimal or no significant downtime. Temporary redness, warmth, swelling or sensitivity may occur.

When can results be seen?

Some patients may notice early firmness following treatment. Progressive improvement may develop over the following weeks and months as collagen remodelling continues.

How many treatments are required?

The appropriate number of treatments depends on skin condition, degree of laxity, treatment area and clinical objectives. A qualified practitioner should recommend an individualized treatment plan.

Which Effector should be used?

Effector selection depends on the size, contour and thickness of the treatment area. XERF provides 5 × 10 mm, 10 × 10 mm, 20 × 20 mm and 20 × 30 mm options.

Are 600 shots always equivalent between different RF systems?

No. Shot count alone does not determine total treatment energy. Effector size, pulse energy, depth, output level and accumulated delivered energy should also be considered.

Can patients return to daily activities after treatment?

Most patients can return to normal activities shortly after treatment, subject to their individual skin response and practitioner’s instructions.

Is XERF safe?

XERF incorporates impedance synchronization, surface-temperature monitoring, adjustable RF levels, three-level ICD cooling and system alerts to support controlled treatment. The system must be operated by appropriately trained professionals according to the operator’s manual.


Important Safety Information

XERF must be operated by trained professionals after reviewing the patient’s medical history and suitability for treatment.

The system must not be used on patients with:

  • A cardiac pacemaker
  • An automatic implantable cardioverter-defibrillator
  • Other implanted electrical devices

Additional contraindications, warnings and precautions in the official operator’s manual must be reviewed before treatment.

شحن & معلومات التسليم

وقت التسليم المقدر
عادة ما يتم تسليم الطلبات داخل 3-8 أيام عمل بعد الدفع، اعتمادا على ظروف التسليم المحلية.

طرق الشحن
نحن نعمل مع رعاة الدولية الموثوقة لضمان توصيل سريع وآمن:

  • Express (DHL ، UPS ، FedEx ، TNT ، EMS): 5-10 أيام عمل.
    ملاحظة: لا يتم تضمين التخليص الجمركي وواجبات الاستيراد. العملاء مسؤولون عن هذه التكاليف.

  • البريد الجوي: 10-18 أيام عمل.
    في معظم الحالات ، يتم تضمين التخليص الجمركي والضرائب. لأنه في بعض البلدان ، قد يكون التصريح صعبًا ، لذا يرجى التأكيد معنا قبل اختيار هذا الخيار.

  • شحن البحر: 1-2 أشهر (قد تستغرق بعض الوجهات أطول من شهرين).
    يتضمن هذا الخيار بشكل عام التخليص الجمركي وضريبة الرسوم. نوصي بشحن البحر إذا لم يكن طلبك عاجلاً وتفضل انخفاض تكلفة الشحن.

رسوم الشحن
يتم حساب تكلفة الشحن بناءً على الوزن والأبعاد والوجهة من طلبك.

التتبع
أ عدد تتبع سيتم تقديمه بمجرد شحن طلبك.

سيتم تقديم رقم التتبع لك بمجرد شحنه. قراءة كاملة سياسة الشحن.

نقدم ضمان استرداد الأموال لمدة 30 يومًا لجميع المنتجات، اقرأ كاملاً سياسة استرداد الأموال.

شركة Mico Aes Technology Co.Ltd، ومقرها الصين، قوانغتشو، لدينا 5 مصانع بخطوط إنتاج مختلفة، واحد لآلات الليزر ذات الصمام الثنائي، والثاني لآلات الهايفو، والثالث لأجهزة الوجه المائية، والرابع لمعدات emszero، والخامس لآلات co2 ماكينات الليزر والبيكو ليزر. نحن نراقب بعناية عمليات التصنيع ونقوم بفحص مراقبة الجودة لكل آلة قبل إرسالها إلى شركة الشحن. يقوم موظفو Mico Aes أيضًا بزيارة كل مصنع بشكل متكرر لإجراء فحوصات عشوائية للجودة لضمان استيفاء معاييرنا المتميزة. تعرف على المزيد من التفاصيل >>>

  • تصنيع & ضبط الجودة

    • عملية التصنيع الصارمة: يتم مراقبة وفحص كل آلة بعناية.
    • فحص شخصي 100%: يخضع كل منتج لفحوصات الجودة الشاملة قبل الشحن.
    • التفتيش العشوائي على المصانع: يقوم موظفو Mico Aes بزيارات متكررة للموقع لضمان الجودة.
  • أجزاء عالية الجودة

    • المصادر العالمية: مكونات من موردين موثوقين في الولايات المتحدة الأمريكية وألمانيا واليابان وكوريا.
    • التصنيع الداخلي: يتم إنتاج بعض الأجزاء في مصانع Mico Aes لتلبية معايير الجودة العالية.

لدينا شهادات CE، Rohs، FCC، وFDA، وبراءات الاختراع للتصميم. شهادات كاملة

شهادات Mico Aes

تلتزم شركة Mico Aes بتوفير أفضل معدات الصالون. سواء كان الأمر مخصصًا لشركتك أو لاستخدامك الشخصي، فأنت بحاجة إلى أن تعمل أجهزتك بفعالية وموثوقية لسنوات قادمة.

  • فترة الضمان للجهاز الرئيسي: سنة واحدة من تاريخ التسليم
  • فترة ضمان قطع الغيار: 3 أشهر من تاريخ التسليم
  • دعم الصيانة مدى الحياة بعد فترة الضمان: ستواصل شركة Mico Aes تقديم المشورة الفنية وقطع الغيار مجانًا بسعر التكلفة.

اقرأ سياسة الضمان الكاملة

طلب الدعم الفني

لضمان تحقيق أفضل النتائج لعملائك، نحن نقدم الوصول الكامل إلى مجموعة واسعة من الموارد التعليمية، مشتمل أدلة المستخدم, فيديوهات العلاج, البروتوكولات، و مواد تسويقية. تم تصميم هذه الموارد لمساعدتك على فهم معداتك الجديدة والترويج لخدماتك بشكل فعال.

نقدم أيضًا شهادة مجانية (شهادة يمكنك تعليقها على الحائط).

اتصل بنا بعد أن تتلقى التسليم الخاص بك لتحديد موعد الجلسة التدريبية الخاصة بك عن طريق Zoom أو FaceTime.

اطرح سؤالاً حول هذا المنتج في أي وقت.

يمكننا قبول الدفع من خلال Paypal (أقل من 1000 دولار أمريكي)، ويسترن يونيون, غرام المال، و التحويل البنكي T/T.

سياسات الدفع الكامل

اقرأ جميع تقييمات Mico Aes التي تم التحقق منها

يمكنك مشاهدة المزيد من التقييمات هنا: https://micoaes.com/testimonials/

عربة التسوق
XERF (5)XERF Dual Frequency 6.78 MHz + 2 MHz Monopolar RF Machine
$8,999.00
دولارات الولايات المتحدة ($) - USD
  • دولارات الولايات المتحدة ($) - USD
  • يورو (€) - EUR
  • جنيه إسترليني (£) - GBP
- +
انتقل إلى أعلى