• Treinamento gratuito + Protocolos & Vídeos
  • Sowns de alimentação de grau médico Meanwell
  • Personalização gratuita do logotipo
  • 12 meses garantia + Serviço de manutenção ao longo da vida Apoiar
  • 24/07 Contato Serviço
  • Frete grátis em todo o mundo

Calculadora de ROI



XERF Dual Frequency 6.78 MHz + 2 MHz Monopolar RF Machine

  • Short Description
  • XERF is a professional dual-frequency monopolar RF system combining 6.78 MHz and 2 MHz for multi-depth skin tightening. With Shallow, Middle and Deep treatment modes, it delivers controlled thermal energy from the dermis toward deeper supporting tissue.
  • Principais recursos
  • Dual-frequency monopolar RF: 6.78 MHz + 2 MHz
  • Shallow, Middle and Deep treatment modes
  • 10 adjustable energy levels
  • Up to 150 W RF output
  • Real-time impedance synchronization
  • Surface-temperature and energy monitoring
  • Wave Fit multi-pulse energy delivery
  • Three-level ICD cooling
  • Four Effector sizes for precise and large-area treatment
  • Suitable for the face, jawline, submental area and neck
  • Tratamento não invasivo com tempo de inatividade mínimo

Frete grátis + Treinamento gratuito

$8.999,00

Dollar dos Estados Unidos ($) - USD
  • Dollar dos Estados Unidos ($) - USD
  • Euro (€) - EUR
  • Libra Sterling (£) - GBP
- +
Descrição

XERF Dual-Frequency Monopolar RF System

Multi-Depth RF Skin Tightening with 6.78 MHz and 2 MHz

XERF is a non-invasive monopolar radiofrequency system designed to deliver controlled thermal energy across multiple tissue depths.

Ao combinar 6.78 MHz and 2 MHz RF frequencies, XERF provides three selectable thermal diffusion modes—Shallow, Middle, and Deep—allowing practitioners to adapt treatment according to tissue thickness, anatomical area, and individual skin characteristics.

With real-time impedance synchronization, adjustable RF output, surface-temperature monitoring, Wave Fit Pulse technology, and three-level ICD cooling, XERF supports precise energy delivery while helping improve treatment comfort and epidermal protection.

XERF (10) (1)

Principais recursos

  • Dual-frequency monopolar RF: 6.78 MHz and 2 MHz
  • Shallow, Middle, and Deep treatment modes
  • Ten adjustable RF output levels
  • Real-time impedance synchronization
  • Wave Fit multi-pulse energy delivery
  • Three-level ICD cooling
  • Surface-temperature monitoring
  • Four Effector sizes
  • Tratamento não invasivo
  • Minimal or no significant downtime

Why Skin Becomes Loose

Skin firmness and elasticity depend on an organized extracellular matrix containing collagen, elastin, fibroblasts, and other structural components.

With age and environmental exposure, the skin gradually experiences:

  • Reduced Type I and Type III collagen
  • Fragmentation of existing collagen fibres
  • Decreased elastin organization
  • Lower fibroblast activity
  • Reduced extracellular matrix renewal
  • Changes in subcutaneous tissue support
  • Progressive weakening of facial contours

These changes can lead to:

  • Linhas finas e rugas
  • Reduced skin elasticity
  • Bochechas caídas
  • Loss of jawline definition
  • Loose skin around the face and neck
  • Changes in facial volume and tissue support

Effective skin-tightening treatments should therefore address more than the visible surface. Controlled energy must be delivered into the appropriate tissue depths to initiate collagen contraction and longer-term tissue remodelling.


Why Monopolar RF?

Monopolar radiofrequency delivers electrical energy from the treatment electrode through the tissue toward a return electrode.

As RF energy passes through tissue, electrical resistance converts the energy into controlled heat.

The RF Tissue-Remodelling Process

Monopolar RF Energy

Electrical Resistance within Tissue

Controlled Thermal Energy

Immediate Collagen Fibre Contraction

Ativação de fibroblastos

Collagen and Elastin Remodelling

Progressive Improvement in Skin Firmness

The controlled thermal response can cause existing collagen fibres to contract while stimulating the biological processes involved in collagen renewal and reorganization.

Some patients may notice an initial feeling of firmness after treatment. Further improvements may develop gradually as collagen remodelling continues over the following weeks and months.

Results vary according to individual skin condition, treatment area, selected parameters, number of shots, and treatment plan.


Why Dual-Frequency RF?

Traditional monopolar RF platforms commonly operate at a single frequency, creating a relatively fixed thermal profile.

However, facial and body anatomy is not uniform. The forehead, cheeks, jawline, neck, abdomen, and thighs differ in:

  • Skin thickness
  • Connective tissue density
  • Subcutaneous fat distribution
  • Surface contours
  • Electrical impedance
  • Required treatment depth

XERF combines 6.78 MHz and 2 MHz monopolar RF to provide greater flexibility in the distribution of thermal energy.

The practitioner can select Shallow, Middle, or Deep mode based on the treatment area and desired degree of thermal diffusion.

XERF (15)
XERF (15)

Why 6.78 MHz?

The 6.78 MHz frequency is used in both Shallow and Middle modes.

By changing the system parameters, XERF can use the same frequency to create different degrees of thermal diffusion.

Shallow Mode

Shallow mode applies 6.78 MHz using parameters designed to produce the lowest degree of thermal diffusion among the three modes.

It may be selected for:

  • Testa
  • Periorbital region
  • Areas around the mouth
  • Narrow facial areas
  • Relatively thin tissue

Treatment objectives may include:

  • Supporting dermal collagen remodelling
  • Improving the appearance of fine lines
  • Enhancing superficial skin firmness
  • Refining skin texture

Middle Mode

Middle mode also applies 6.78 MHz but uses parameters designed to create moderate thermal diffusion.

It may be selected for:

  • Bochechas
  • Lower face
  • Pescoço
  • Areas with moderate tissue thickness
  • General facial tightening

Treatment objectives may include:

  • Improving skin elasticity
  • Supporting facial contour definition
  • Addressing mild to moderate skin laxity
  • Creating more comprehensive dermal heating

Why Add 2 MHz?

Lower-frequency RF can create a broader and deeper thermal field.

In XERF Deep mode, 6.78 MHz and 2 MHz are delivered sequentially, producing the deepest thermal diffusion of the three selectable modes.

Deep Mode

Deep mode may be selected for:

  • Lower face
  • Mandíbula
  • Submental area
  • Areas with thicker subcutaneous tissue
  • Deeper structural tightening objectives

Official histological research cited by Lutronic reported collagen changes extending from the dermis through deeper subcutaneous tissue toward the fascial or SMAS region following combined 6.78 MHz and 2 MHz RF application.

The treatment objective is not simply to heat a single layer, but to create a controlled multi-depth thermal response according to the patient’s anatomy.


Three Depths, One Personalized Treatment

XERF allows the practitioner to combine three thermal diffusion modes within one treatment plan.

Treatment mode Frequência RF Thermal diffusion Typical treatment consideration
Shallow 6,78MHz Lowest thermal diffusion Thin, narrow or delicate areas
Middle 6,78MHz Moderate thermal diffusion General facial and neck treatment
Profundo 6.78 MHz followed by 2 MHz Deepest thermal diffusion Thicker tissue and deeper structural support

The appropriate mode should be selected by a trained practitioner following an assessment of:

  • Área de tratamento
  • Tissue thickness
  • Flacidez da pele
  • Conforto do paciente
  • Clinical objective
  • Previous treatments
  • Relevant medical history

Wave Fit Pulse Technology

Controlled Energy Delivery with Coordinated Cooling

The effectiveness of monopolar RF depends not only on peak energy, but also on how that energy is distributed and maintained within the tissue.

Traditional fixed-pulse systems may deliver energy through a smaller number of concentrated pulses, potentially producing a rapid increase in temperature and greater discomfort.

XERF’s Wave Fit Pulse technology distributes RF energy across multiple controlled sub-pulses. Depending on the selected treatment setting, energy may be divided into up to 12 pulses.

ICD cooling is coordinated with the pulse sequence to support:

  • A more gradual temperature increase
  • Controlled thermal accumulation
  • Improved epidermal protection
  • More stable energy delivery
  • Greater treatment comfort

The system adapts pulse delivery according to the selected RF energy and treatment parameters, helping maintain a balance between heating and cooling.


Three-Level ICD Cooling

XERF incorporates an Integrated Cryogen Delivery cooling system at the treatment tip.

The ICD system uses controlled refrigerant-gas delivery to cool the treatment surface and help protect the epidermis during RF application.

Practitioners can select three ICD cooling levels:

  • ICD Level 1
  • ICD Level 2
  • ICD Level 3

The cooling level can be adjusted according to:

  • Effector type
  • Selected depth
  • Nível de energia
  • Área de tratamento
  • Tissue response
  • Patient feedback

Additional ICD cooling may be selected when greater surface protection or improved comfort is required.

The main unit also uses an internal air-cooling system. The internal system cooling and the ICD treatment-tip cooling are separate functions.


Real-Time Impedance Synchronization

Electrical impedance differs between patients and can also vary across anatomical regions.

Before RF energy is delivered, XERF performs an impedance synchronization process by placing the Effector in contact with the treatment area.

The system evaluates the impedance of the treatment area and synchronizes RF delivery accordingly.

This supports:

  • More consistent RF energy transmission
  • Area-specific treatment settings
  • Personalized energy delivery
  • Improved treatment reproducibility
  • Detection of unsuitable electrode contact

If impedance synchronization is unsuccessful, the system returns to standby and requires the process to be repeated before RF output can continue.


Surface-Temperature and Energy Monitoring

After each RF shot, the practitioner can review important treatment information on the graphical user interface and handpiece display.

Displayed treatment data include:

  • Tip-surface temperature
  • Energy delivered in a single pulse
  • Total accumulated delivered energy
  • Shot count
  • Selected treatment depth
  • RF output level
  • ICD cooling level

This real-time information helps practitioners monitor treatment progress and make appropriate adjustments during the procedure.

Surface-temperature monitoring should be used together with continuous observation of tissue response and patient feedback.


Intuitive Treatment Interface

The 10.1-inch LCD touchscreen provides direct access to the principal treatment parameters.

Practitioners can control:

  • Shallow, Middle, or Deep mode
  • RF output Level 1–10
  • ICD cooling Level 1–3
  • Shot interval
  • Finger-switch or foot-switch activation
  • Impedance synchronization
  • Effector information
  • Delivered pulse energy
  • Accumulated energy
  • Tip-surface temperature
  • Treatment progress

The shot interval can be set to:

  • Off
  • 200 ms
  • 500 ms
  • 800 ms

When the interval is turned off, the system delivers one RF shot each time the finger switch or foot switch is activated.


Four XERF Effectors

XERF offers four disposable Effector sizes for different treatment areas and tissue contours.

Effector Contact size Maximum RF energy Available shot configurations Recommended application
Effector 05 5 × 10 mm 18.7 J 600 Narrow, thin and precise areas
Effector 10 10 × 10 mm 38.1 J 600 Small or curved facial areas
Effector 40 20 × 20 mm 140 J 600 General facial and neck coverage
Effector 60 20 × 30 mm 220 J 600 Large or thicker treatment areas

XERF (11)

Effector 05

The 5 × 10 mm Effector is designed for narrow and relatively thin treatment areas where precise contact is important.

Possible applications include:

  • Areas around the eyes
  • Areas around the mouth
  • Narrow facial contours
  • Small localized treatment zones

Effector 10

The 10 × 10 mm Effector provides controlled contact over small or curved areas.

Possible applications include:

  • Forehead contours
  • Lower face
  • Perioral region
  • Localized facial laxity

Effector 40

The 20 × 20 mm Effector is suitable for efficient general facial coverage.

Possible applications include:

  • Bochechas
  • Testa
  • Mandíbula
  • Pescoço

Effector 60

The 20 × 30 mm Effector provides a treatment area 1.5 times larger than a conventional 20 × 20 mm tip.

Its larger electrode surface allows more energy to be delivered over a broader area per shot.

Possible applications include:

  • Broad facial areas
  • Lower face
  • Submental area
  • Larger or thicker treatment zones

Treatment effectiveness should not be evaluated only by the number of shots. Effector size, pulse energy, accumulated delivered energy, treatment depth, and tissue characteristics must also be considered.


Spider-Pattern Electrode Design

The XERF Effector incorporates a distinctive spider-pattern electrode.

The distributed electrode structure is designed to support more uniform energy delivery across the contact surface and reduce excessive concentration of RF energy around the edge of the electrode.

This design supports:

  • More even RF distribution
  • Stable tissue contact
  • Reduced edge concentration
  • Controlled treatment of curved areas
  • Improved epidermal protection

The Effector must remain in proper contact with the skin throughout RF delivery.


Clinical Science

Multi-Layer Collagen Response

Official research cited by Lutronic evaluated tissue changes following the application of combined 6.78 MHz and 2 MHz RF energy.

Reported histological observations included:

  • Collagen fibre thickening
  • Collagen fibre shortening
  • Thermal changes within the dermis
  • Changes extending into deeper subcutaneous tissue
  • Collagen response near the deep fascial or SMAS region
  • Continued tissue remodelling following treatment

The research supports the concept that combining two monopolar RF frequencies can produce a deeper and more comprehensive thermal profile than a single 6.78 MHz frequency alone.

Immediate and Progressive Response

Controlled RF heating may cause an immediate contraction of existing collagen structures.

Longer-term improvement is associated with:

  • Fibroblast activation
  • Neocollagenesis
  • Collagen reorganization
  • Gradual improvement in tissue density
  • Progressive contour refinement

Improvements may continue to develop after treatment as the tissue-remodelling process progresses.

No specific result can be guaranteed, and individual responses vary.


Áreas de Tratamento

XERF may be used by qualified practitioners to address suitable facial and neck areas, including:

  • Testa
  • Periorbital area
  • Bochechas
  • Nasolabial region
  • Perioral area
  • Lower face
  • Mandíbula
  • Papadas
  • Submental area
  • Pescoço

Depending on the local regulatory status, available Effectors and authorized indications, larger treatment areas may also be considered.

The practitioner should select the Effector, depth, output level and cooling setting according to the individual treatment area.


Treatment Objectives

XERF may support improvements in the appearance of:

  • Frouxidão leve a moderada
  • Reduced facial definition
  • Loose skin around the jawline
  • Bochechas caídas
  • Linhas finas
  • Rugas
  • Reduced skin elasticity
  • Uneven skin firmness
  • Loose skin around the neck
  • Age-related changes in facial contours

XERF is not a substitute for surgery and does not produce surgical facelift results.


Who May Be Suitable for XERF?

XERF may be considered for adults who:

  • Have mild to moderate skin laxity
  • Want non-invasive skin tightening
  • Prefer minimal or no significant downtime
  • Want to improve facial contour definition
  • Are concerned about loose skin around the face or neck
  • Want a treatment that can be adapted to different tissue depths
  • Prefer a treatment designed to reduce heat-related discomfort
  • Want to incorporate RF treatment into an ongoing skin-maintenance plan

A professional consultation is required to determine whether the treatment is appropriate.


XERF Treatment Process

1. Consultation

Before treatment, the practitioner evaluates:

  • Condição da pele
  • Grau de frouxidão
  • Tissue thickness
  • Objetivos do tratamento
  • História médica
  • Previous procedures
  • Contra -indicações
  • Expected treatment response

Clinical photographs may be taken for treatment planning and follow-up comparison.

2. Skin Preparation

The treatment area is cleaned and all relevant accessories are checked.

A patient return pad is connected and positioned according to the operator’s manual.

A thin layer of ultrasound coupling gel is applied to the treatment area. RF treatment must not be performed on dry tissue without the required coupling gel.

3. Parameter Selection

The practitioner selects:

  • Effector size
  • Shallow, Middle, or Deep mode
  • RF output level
  • ICD cooling level
  • Shot interval
  • Activation method

Parameters must be adjusted according to the anatomical area, tissue thickness and patient feedback.

4. Impedance Synchronization

The Effector is placed in contact with the treatment area and the impedance synchronization process is completed.

RF output cannot proceed until successful synchronization has been confirmed.

5. RF Energy Delivery

The practitioner maintains full contact between the Effector and the skin and activates RF delivery through the handpiece switch or foot switch.

During treatment, the practitioner monitors:

  • Conforto do paciente
  • Resposta da pele
  • Surface temperature
  • Pulse energy
  • Accumulated energy
  • Electrode contact
  • Treatment symmetry

6. Post-Treatment Assessment

After treatment, the coupling gel is removed and the skin is evaluated.

Temporary warmth, redness, mild swelling or sensitivity may occur. These reactions are generally transient but should be monitored according to professional protocols.


Tempo de tratamento

Treatment time depends on:

  • Área de tratamento
  • Effector size
  • Number of shots
  • Selected depth
  • Nível de energia
  • Individual treatment plan

A typical facial treatment may take approximately 15–30 minutos, although larger or combined treatment areas may require additional time.


Does XERF Require Anesthesia?

XERF is designed to balance RF energy delivery with coordinated ICD cooling.

Many treatments can be performed without anesthesia. Patients generally experience a warm sensation during RF delivery.

Sensitivity varies between individuals, and the practitioner should assess patient comfort throughout the procedure. The use of topical anesthesia should follow the treatment protocol and applicable clinical requirements.


Downtime and Aftercare

XERF is non-invasive and generally involves minimal or no significant downtime.

Most patients can return to normal daily activities shortly after treatment.

Possible temporary responses include:

  • Vermelhidão
  • Warmth
  • Mild swelling
  • Tenderness
  • Temporary sensitivity

General aftercare may include:

  • Avoiding excessive heat immediately after treatment
  • Avoiding aggressive exfoliation until the skin feels normal
  • Applying gentle skincare products
  • Using broad-spectrum sunscreen
  • Following the practitioner’s individual instructions

Makeup may generally be applied once the skin is comfortable and there is no significant irritation.


XERF vs Traditional Single-Frequency Monopolar RF

Recurso Traditional single-frequency RF XERF dual-frequency RF
Frequência RF Usually one fixed frequency 6.78 MHz and 2 MHz
Depth selection Relatively fixed thermal profile Shallow, Middle and Deep modes
Deep mode Limited by single-frequency delivery Sequential 6.78 MHz and 2 MHz
Entrega de energia May use a fixed pulse structure Wave Fit multi-pulse delivery
Resfriamento Depends on the platform Three-level ICD cooling
Impedance feedback Depends on the platform Impedance synchronization
Temperature monitoring Depends on the platform Tip-surface temperature display
Output adjustment Platform dependent Ten output levels
Treatment tips Limited or fixed sizes Four Effector sizes
Treatment customization More limited Area- and tissue-specific selection

The clinical performance of any RF treatment depends on the system configuration, operator technique, selected parameters and individual patient characteristics.


Especificações Técnicas

Especificação XERF
RF type Monopolar RF
Frequências 2 MHz and 6.78 MHz
Maximum RF output at rated load 2 MHz: 150 W @ 200 Ω
6.78 MHz: 140 W @ 200 Ω
Maximum RF output at reference load 2 MHz: 129 W @ 100 Ω
6.78 MHz: 125 W @ 100 Ω
RF output levels Level 1–10
Treatment depths Shallow / Middle / Deep
Shot intervals Off / 200 / 500 / 800 ms
ICD cooling Level 1–3
System cooling Resfriamento de ar
User interface 10.1-inch LCD touchscreen
Dimensões 389 mm W × 856.4 mm L × 1604.1 mm H
Peso 47 kg
Electrical classification Class I, Type BF applied part
Electrical rating Single-phase AC 100–120 V, 50/60 Hz
Consumo de energia 1 kVA
RF activation Handpiece finger switch or foot switch
Treatment electrode Disposable XERF Effector
Patient circuit Patient return pad

Specifications may vary according to the market, device version and regulatory configuration.


Perguntas frequentes

What is XERF?

XERF is a non-invasive monopolar RF system that combines 6.78 MHz and 2 MHz frequencies to create Shallow, Middle and Deep thermal diffusion modes.

How is XERF different from conventional monopolar RF?

Conventional platforms commonly use one RF frequency. XERF uses 6.78 MHz and 2 MHz, allowing the practitioner to select different thermal diffusion depths according to the treatment area and tissue characteristics.

How does Deep mode work?

Deep mode delivers 6.78 MHz and 2 MHz sequentially, creating the deepest thermal diffusion of the three available modes.

Does XERF reach the SMAS?

Official histological research cited by Lutronic reported collagen changes extending toward the deep fascial or SMAS region after combined 6.78 MHz and 2 MHz RF application. Actual energy distribution depends on the selected parameters and individual tissue characteristics.

Is XERF painful?

Patients generally experience warmth during treatment. Wave Fit Pulse and ICD cooling are designed to reduce discomfort and control surface heating. Individual sensitivity varies.

Is anesthesia required?

Many treatments can be performed without anesthesia. The practitioner should determine the appropriate comfort-management approach for each patient.

How long does treatment take?

A typical treatment takes approximately 15–30 minutes. Treatment time varies according to the area and number of shots.

Existe algum tempo de inatividade?

XERF is non-invasive and generally requires minimal or no significant downtime. Temporary redness, warmth, swelling or sensitivity may occur.

When can results be seen?

Some patients may notice early firmness following treatment. Progressive improvement may develop over the following weeks and months as collagen remodelling continues.

How many treatments are required?

The appropriate number of treatments depends on skin condition, degree of laxity, treatment area and clinical objectives. A qualified practitioner should recommend an individualized treatment plan.

Which Effector should be used?

Effector selection depends on the size, contour and thickness of the treatment area. XERF provides 5 × 10 mm, 10 × 10 mm, 20 × 20 mm and 20 × 30 mm options.

Are 600 shots always equivalent between different RF systems?

No. Shot count alone does not determine total treatment energy. Effector size, pulse energy, depth, output level and accumulated delivered energy should also be considered.

Can patients return to daily activities after treatment?

Most patients can return to normal activities shortly after treatment, subject to their individual skin response and practitioner’s instructions.

Is XERF safe?

XERF incorporates impedance synchronization, surface-temperature monitoring, adjustable RF levels, three-level ICD cooling and system alerts to support controlled treatment. The system must be operated by appropriately trained professionals according to the operator’s manual.


Important Safety Information

XERF must be operated by trained professionals after reviewing the patient’s medical history and suitability for treatment.

The system must not be used on patients with:

  • A cardiac pacemaker
  • An automatic implantable cardioverter-defibrillator
  • Other implanted electrical devices

Additional contraindications, warnings and precautions in the official operator’s manual must be reviewed before treatment.

Envio & Informações de entrega

Tempo de entrega estimado
Os pedidos geralmente são entregues dentro 3-8 dias úteis após o pagamento, dependendo das condições de entrega local.

Métodos de envio
Trabalhamos com correios internacionais confiáveis para garantir uma entrega rápida e segura:

  • Express (DHL, UPS, FedEx, TNT, EMS): 5-10 dias úteis.
    Nota: A liberação aduaneira e os direitos de importação não estão incluídos. Os clientes são responsáveis por esses custos.

  • Correio aéreo: 10–18 dias úteis.
    Na maioria dos casos, a liberação aduaneira e os impostos estão incluídos. Porque em certos países, a liberação pode ser difícil, por isso, confirme conosco antes de escolher essa opção.

  • Frete marítimo: 1 a 2 meses (alguns destinos podem levar mais de 2 meses).
    Essa opção geralmente inclui liberação aduaneira e imposto de serviço. Recomendamos o transporte marítimo se o seu pedido não for urgente e você preferir um custo de envio mais baixo.

Taxa de envio
O custo de envio é calculado com base no peso, dimensões e destino do seu pedido.

Monitorando
UM Número de rastreamento será fornecido assim que seu pedido for enviado.

O número de rastreamento será oferecido a você assim que for enviado. Leia completo política de envio.

Oferecemos uma garantia de devolução do dinheiro em 30 dias para todos os produtos, leia na íntegra Politica de reembolso.

Mico Aes Technology Co,.Ltd, com sede na China, Guangzhou, temos 5 fábricas com diferentes linhas de produção, uma para máquinas de laser de diodo, a segunda para máquinas hifu, a terceira para dispositivos hidrofaciais e a quarta para equipamentos emszero e a quinta para co2 máquinas laser e pico laser. Estamos monitorando cuidadosamente os processos de fabricação e verificando o controle de qualidade de cada máquina antes de enviar para a transportadora. Os funcionários da Mico Aes também visitam frequentemente cada uma das fábricas para fazer inspeções de qualidade aleatórias e garantir que nossos padrões premium sejam atendidos. Saiba mais detalhes >>>

  • Fabricação & Controle de qualidade

    • Processo de fabricação rigoroso: Cada máquina é cuidadosamente monitorada e inspecionada.
    • Inspeção 100% Pessoal: Cada produto passa por verificações de qualidade completas antes do envio.
    • Inspeções aleatórias de fábrica: Os funcionários da Mico Aes realizam visitas frequentes ao local para garantia de qualidade.
  • Peças de alta qualidade

    • Fornecimento Global: Componentes de fornecedores confiáveis ​​nos EUA, Alemanha, Japão e Coréia.
    • Fabricação Interna: Algumas peças são produzidas nas fábricas da Mico Aes para atender a altos padrões de qualidade.

Temos certificados CE, Rohs, FCC e FDA e patentes de design. Certificados completos

certificados de Mico Aes

A Mico Aes tem o compromisso de fornecer equipamentos de salão da melhor qualidade. Quer seja para o seu negócio ou para uso pessoal, você precisa que suas máquinas funcionem de maneira eficaz e confiável por muitos anos.

  • Período de garantia para a máquina principal: 1 ano a partir da data de entrega
  • Período de garantia para peças de reposição: 3 meses a partir da data de entrega
  • Suporte de manutenção vitalício após o período de garantia: A Mico Aes continuará a fornecer consultoria técnica gratuita e peças a preço de custo.

Leia a política de garantia completa

Solicitar suporte técnico

Para garantir que você obtenha os melhores resultados para seus clientes, oferecemos acesso completo para uma ampla gama de recursos educacionais, incluindo manuais do usuário, vídeos de tratamento, protocolos, e materiais de marketing. Esses recursos foram projetados para ajudá-lo a compreender seu novo equipamento e promover seus serviços de maneira eficaz.

Também oferecemos certificação gratuita (certificado que você pode pendurar na parede).

Contate-nos após receber sua entrega para agendar seu treino por Zoom ou FaceTime.

Faça uma pergunta sobre este produto a qualquer momento.

Podemos aceitar pagamento através do Paypal (menos de 1000USD), Western Union, Grama de dinheiro, e Transferência bancária T/T.

Políticas de pagamento completas

Leia todas as avaliações verificadas da Mico Aes

Você pode ver mais comentários aqui: https://micoaes.com/testimonials/

Carrinho de compras
XERF (5)XERF Dual Frequency 6.78 MHz + 2 MHz Monopolar RF Machine
$8.999,00
Dollar dos Estados Unidos ($) - USD
  • Dollar dos Estados Unidos ($) - USD
  • Euro (€) - EUR
  • Libra Sterling (£) - GBP
- +
Role para cima