XERF-Style Dual Frequency 6.78 MHz + 2 MHz Monopolar RF Machine

  • Short Description
  • XERF is a professional dual-frequency monopolar RF system combining 6.78 MHz and 2 MHz for multi-depth skin tightening.
  • With Shallow, Middle, and Deep treatment modes, it delivers controlled thermal energy from the dermis toward deeper supporting tissue.
  • Key Features
  • Dual-frequency monopolar RF: 6.78 MHz + 2 MHz
  • Shallow, Middle and Deep treatment modes
  • 10 adjustable energy levels
  • Up to 150 W RF output
  • Real-time impedance synchronization
  • Surface-temperature and energy monitoring
  • Wave Fit multi-pulse energy delivery
  • Three-level ICD cooling
  • Four Effector sizes for precise and large-area treatment
  • Suitable for the face, jawline, submental area and neck
  • Non-invasive treatment with minimal downtime

Free Shipping + Free  Training 

Original price was: $8,999.00.Current price is: $6,999.00.

United States dollar ($) - USD
  • United States dollar ($) - USD
  • Euro (€) - EUR
  • Pound sterling (£) - GBP
- +

Certified Factory

CE Certified · ISO 13485 Quality System

1-Year Warranty

Lifetime Remote Support

Spare Parts Support

Repair & Replacement

Pre-Shipment QC

Energy-Tested Before Shipping

Operator Training

Manuals & Protocols

OEM / Distributor

Branding & Bulk Orders

Description

XERF Dual-Frequency Monopolar RF System

6.78 MHz and 2 MHz monopolar RF for professional use

XERF is a non-invasive monopolar RF system with three thermal diffusion modes for different treatment areas and tissue thicknesses. It combines Wave Fit multi-pulse delivery, impedance synchronization, surface-temperature monitoring, and adjustable ICD cooling.

The standard package includes four Effector sizes, with 40 Effectors in total, plus patient return pads, video training, and operating documentation.

XERF (10) (1)

How it works

Monopolar RF delivers electrical energy from a treatment electrode through the tissue to a patient return electrode. Tissue resistance converts this energy into heat, which can produce collagen contraction and support subsequent tissue remodelling.

Skin thickness, tissue composition, and contours vary across the face and neck. XERF uses two frequencies and three selectable modes to adjust thermal diffusion to the treatment area.

For a broader look at RF technology, read our monopolar RF vs bipolar RF comparison.

Mode RF frequency Relative thermal diffusion Treatment considerations
Shallow 6.78 MHz Lowest of the three modes Thin, narrow, or delicate areas
Middle 6.78 MHz Moderate General facial and neck treatment
Deep 6.78 MHz followed by 2 MHz Deepest of the three modes Lower face, jawline, submental area, and thicker tissue

Practitioners select the mode according to the patient’s anatomy, skin condition, medical history, and treatment goals.

XERF (15)

Four disposable Effectors

XERF (11)

Effector Contact dimensions Maximum RF energy Shot count Typical application
Effector 05 5 × 10 mm 18.7 J 600 Small, narrow treatment areas
Effector 10 10 × 10 mm 38.1 J 600 Small or curved facial areas
Effector 40 20 × 20 mm 140 J 600 General facial and neck coverage
Effector 60 20 × 30 mm 220 J 600 Larger areas or thicker tissue

The Effectors use a spider-pattern electrode designed to distribute energy across the contact surface and reduce concentration at the edges. Proper skin contact must be maintained during RF delivery.

Effector selection depends on the area’s size, contours, and tissue thickness. Shot count alone does not indicate treatment energy; contact size, pulse energy, accumulated energy, and treatment mode also matter.

Treatment areas and objectives

Potential treatment areas include the forehead, periorbital and perioral regions, cheeks, lower face, jawline, jowls, submental area, and neck. Treatment must follow the device’s authorized indications and local requirements.

Treatment objectives may include improving the appearance of mild to moderate skin laxity, fine lines, reduced elasticity, and loss of facial definition.

Some patients may notice early firmness, with further changes developing over the following weeks and months. Results vary with skin condition, treatment settings, operator technique, and the treatment plan. XERF is not a substitute for surgery and does not produce surgical facelift results.

Research background

Histological research cited by Lutronic reports collagen changes in the dermis and deeper subcutaneous tissue, including changes toward the deep fascial or SMAS region, following combined 6.78 MHz and 2 MHz RF application. These observations do not guarantee a specific treatment depth or clinical result for every patient.


Why Dual-Frequency RF?

Traditional monopolar RF platforms commonly operate at a single frequency, creating a relatively fixed thermal profile.

However, facial and body anatomy is not uniform. The forehead, cheeks, jawline, neck, abdomen, and thighs differ in:

  • Skin thickness
  • Connective tissue density
  • Subcutaneous fat distribution
  • Surface contours
  • Electrical impedance
  • Required treatment depth
dual-frequency-monopolar-rf-thermal-distribution-xerf
dual-frequency-monopolar-rf-thermal-distribution-xerf

Different treatment areas vary in tissue thickness and contours. Combining 6.78 MHz and 2 MHz gives practitioners more options for adjusting energy delivery to these differences.

Shallow and Middle modes use 6.78 MHz with different settings. Deep mode delivers 6.78 MHz followed by 2 MHz in sequence. The resulting heating pattern depends on pulse timing, energy output, Effector design, cooling, and tissue characteristics—not frequency alone.

For a closer look at the technology, read how 6.78 MHz and 2 MHz dual-frequency monopolar RF works.


Treatment process

  1. Consultation: Assess skin condition, tissue thickness, medical history, previous procedures, contraindications, and treatment goals.
  2. Preparation: Clean the area, position the patient return pad, and apply the required coupling medium according to the operator’s manual.
  3. Parameter selection: Choose the Effector, treatment mode, output level, cooling level, shot interval, and activation method.
  4. Impedance synchronization: Establish proper contact and complete synchronization before delivering RF energy.
  5. Treatment: Maintain full Effector contact while monitoring skin response, patient comfort, temperature, and delivered energy.
  6. Post-treatment assessment: Remove the coupling medium, assess the skin, and provide aftercare instructions.

A typical facial treatment may take approximately 15–30 minutes. Duration varies with the treatment area, Effector, settings, and number of shots.

Many treatments can be performed without anesthesia, although comfort management should be determined by the practitioner. Temporary redness, warmth, swelling, or sensitivity may occur. Patients can generally resume daily activities shortly afterward, subject to their skin response and aftercare instructions.

The number of sessions should be determined during consultation.

For further reading on treatment planning, see our dual-frequency monopolar RF protocol and safety guide. Always follow the operator’s manual for your specific device.

Technical specifications

Specification Details
RF type Monopolar RF
Frequencies 2 MHz and 6.78 MHz
Maximum RF output at rated load 2 MHz: 150 W at 200 Ω; 6.78 MHz: 140 W at 200 Ω
Maximum RF output at reference load 2 MHz: 129 W at 100 Ω; 6.78 MHz: 125 W at 100 Ω
RF output levels 1–10
Treatment modes Shallow, Middle, and Deep
Energy delivery Wave Fit multi-pulse delivery
Shot intervals Off, 200 ms, 500 ms, or 800 ms
ICD cooling levels 1–3
Internal cooling Air cooling
Display 10.1-inch LCD touchscreen
Dimensions 389 mm W × 856.4 mm L × 1604.1 mm H
Weight 47 kg
Electrical classification Class I, Type BF applied part
Power supply Single-phase AC 100–120 V, 50/60 Hz
Power consumption 1 kVA
RF activation Handpiece finger switch or foot switch
Treatment electrode Disposable Effector
Patient circuit Disposable patient return pad

With the shot interval set to Off, each activation delivers one RF shot.

Specifications may differ by device version and market configuration. Confirm the final specification sheet before ordering.

What’s included

Item Quantity
Dual-frequency monopolar RF main unit 1
Effector 05 10
Effector 10 10
Effector 40 10
Effector 60 10
Disposable patient return pads 5
ICD cooling medium Four 800 ml bottles, where shipping is permitted
Video training Included
Operating manuals and treatment guidance Included

Replacement consumables

Consumable Reference price
4 replacement Effectors USD 400
8 replacement Effectors USD 600
30 disposable patient return pads USD 150

Patient return pads are for single use only. Replacement Effectors, return pads, and compatible consumables are available for ongoing supply.

When budgeting for an RF system, consider ongoing consumable costs alongside the purchase price. Our monopolar RF machine cost and clinic ROI guide provides a starting point for assessing the investment.

Compare RF platforms

Comparing equipment for your clinic? Our XERF vs Thermage guide covers energy delivery, cooling, treatment tips, and purchasing considerations.

For a comparison of dual-frequency and single-frequency systems, read XERF vs Volnewmer, which examines RF technology, treatment workflow, and operating costs.

Training and warranty

Video training and documentation cover setup, Effector replacement, return pad connection, treatment settings, cooling, impedance synchronization, cleaning, maintenance, and basic troubleshooting.

The machine includes a one-year warranty and lifetime remote technical support. Warranty coverage, exclusions, replacement parts, and service procedures follow the terms supplied with your order.

Inspection and shipping

Each machine is inspected and tested before dispatch. Shipping costs, delivery options, and trade terms depend on the destination and order configuration.

Cooling-medium shipment is subject to carrier and destination restrictions. Availability and any separate shipping arrangements will be confirmed before the order is finalized.

Professional-use requirements

The system must be operated by trained professionals following the operator’s manual and an assessment of patient suitability.

It must not be used on patients with a cardiac pacemaker, an implantable cardioverter-defibrillator, or other implanted electrical devices. Review the manual for the complete contraindications, warnings, and precautions before treatment.

Request an itemized quote

Send us your destination country, business type, treatment requirements, and order quantity. We will confirm the configuration, consumable pricing, cooling-medium availability, shipping terms, and warranty coverage.

OEM branding, bulk orders, and distributor options are available on request. Include your branding requirements and target market for a project-specific quotation.


Frequently Asked Questions

What is XERF?

XERF is a non-invasive monopolar RF system that combines 6.78 MHz and 2 MHz frequencies to create Shallow, Middle and Deep thermal diffusion modes.

How is XERF different from conventional monopolar RF?

Conventional platforms commonly use one RF frequency. XERF uses 6.78 MHz and 2 MHz, allowing the practitioner to select different thermal diffusion depths according to the treatment area and tissue characteristics.

How does Deep mode work?

Deep mode delivers 6.78 MHz and 2 MHz sequentially, creating the deepest thermal diffusion of the three available modes.

Does XERF reach the SMAS?

Official histological research cited by Lutronic reported collagen changes extending toward the deep fascial or SMAS region after combined 6.78 MHz and 2 MHz RF application. Actual energy distribution depends on the selected parameters and individual tissue characteristics.

Is XERF painful?

Patients generally experience warmth during treatment. Wave Fit Pulse and ICD cooling are designed to reduce discomfort and control surface heating. Individual sensitivity varies.

Is anesthesia required?

Many treatments can be performed without anesthesia. The practitioner should determine the appropriate comfort-management approach for each patient.

How long does treatment take?

A typical treatment takes approximately 15–30 minutes. Treatment time varies according to the area and number of shots.

Is there any downtime?

XERF is non-invasive and generally requires minimal or no significant downtime. Temporary redness, warmth, swelling or sensitivity may occur.

When can results be seen?

Some patients may notice early firmness following treatment. Progressive improvement may develop over the following weeks and months as collagen remodelling continues.

How many treatments are required?

The appropriate number of treatments depends on skin condition, degree of laxity, treatment area and clinical objectives. A qualified practitioner should recommend an individualized treatment plan.

Which Effector should be used?

Effector selection depends on the size, contour, and thickness of the treatment area. XERF provides 5 × 10 mm, 10 × 10 mm, 20 × 20 mm and 20 × 30 mm options.

Are 600 shots always equivalent between different RF systems?

No. Shot count alone does not determine total treatment energy. Effector size, pulse energy, depth, output level and accumulated delivered energy should also be considered.

Can patients return to daily activities after treatment?

Most patients can return to normal activities shortly after treatment, subject to their individual skin response and practitioner’s instructions.

Is XERF safe?

XERF incorporates impedance synchronization, surface-temperature monitoring, adjustable RF levels, three-level ICD cooling, and system alerts to support controlled treatment. The system must be operated by appropriately trained professionals according to the operator’s manual.


Important Safety Information

XERF must be operated by trained professionals after reviewing the patient’s medical history and suitability for treatment.

The system must not be used on patients with:

  • A cardiac pacemaker
  • An automatic implantable cardioverter-defibrillator
  • Other implanted electrical devices

Additional contraindications, warnings and precautions in the official operator’s manual must be reviewed before treatment.

Treatment controls

Choose from Shallow, Middle, and Deep modes, with 10 RF output levels and three ICD cooling settings. Deep mode delivers 6.78 MHz followed by 2 MHz in sequence.

The 10.1-inch touchscreen displays tip-surface temperature, pulse energy, accumulated energy, and shot count. Treatment can be activated using the handpiece finger switch or foot switch.

Feature Configuration
RF technology Monopolar radiofrequency
Frequencies 6.78 MHz and 2 MHz
Treatment modes Shallow, Middle, and Deep
Deep-mode delivery Sequential 6.78 MHz and 2 MHz
RF output Levels 1–10
Energy delivery Wave Fit multi-pulse delivery
Cooling Three-level ICD cooling
Impedance function Real-time impedance synchronization
Monitoring Tip-surface temperature, pulse energy, accumulated energy, and shot count
Display 10.1-inch LCD touchscreen
Activation Handpiece finger switch or foot switch

What’s included

Item Quantity
Dual-frequency monopolar RF main unit 1
Effector 05 10
Effector 10 10
Effector 40 10
Effector 60 10
Disposable patient return pads 5
ICD cooling medium Four 800 ml bottles, where shipping is permitted
Video training Included
Operating manuals and treatment guidance Included

The package contains 40 Effectors in total. Cooling-medium shipment depends on the destination and carrier restrictions. We will confirm availability and shipping arrangements before you finalize your order.

Four Effector sizes

Select the Effector according to the treatment area, tissue thickness, anatomical contours, and planned settings.

Effector Contact dimensions Maximum RF energy Shot count Typical application
Effector 05 5 × 10 mm 18.7 J 600 Small, narrow treatment areas
Effector 10 10 × 10 mm 38.1 J 600 Small or curved facial areas
Effector 40 20 × 20 mm 140 J 600 General facial and neck coverage
Effector 60 20 × 30 mm 220 J 600 Larger areas or thicker tissue

When comparing RF systems, consider contact size, pulse energy, accumulated energy, and treatment mode alongside shot count.

Replacement consumables

Consumable Reference price
4 replacement Effectors USD 400
8 replacement Effectors USD 600
30 disposable patient return pads USD 150

Patient return pads are for single use only. Replacement Effectors, return pads, and other compatible consumables are available for ongoing supply.

All prices are in USD and subject to confirmation when quoted. Shipping, import charges, and local taxes are excluded unless stated in your quotation.

Ask About Consumable Supply

Treatment modes

The three modes provide different thermal diffusion profiles. Practitioners can adjust the mode, Effector, output level, and cooling setting following an individual assessment.

Mode Frequency Relative thermal diffusion Treatment considerations
Shallow 6.78 MHz Lowest of the three modes Thin, narrow, or delicate areas
Middle 6.78 MHz Moderate General facial and neck treatment
Deep 6.78 MHz followed by 2 MHz Highest of the three modes Lower face, jawline, submental area, and thicker tissue

Treatment areas

Potential treatment areas include the forehead, cheeks, perioral area, lower face, jawline, jowls, submental area, and neck. Use depends on practitioner assessment, Effector selection, authorized indications, and local requirements.

Treatment objectives may include improving the appearance of mild to moderate skin laxity, fine lines, and reduced facial definition or firmness.

Results vary with the individual, treatment settings, treatment plan, and operator technique. The system is not a substitute for surgery.

Technical specifications

Specification Details
RF type Monopolar RF
Frequencies 2 MHz and 6.78 MHz
Maximum RF output at rated load 2 MHz: 150 W at 200 Ω; 6.78 MHz: 140 W at 200 Ω
Maximum RF output at reference load 2 MHz: 129 W at 100 Ω; 6.78 MHz: 125 W at 100 Ω
RF output levels 1–10
Treatment modes Shallow, Middle, and Deep
Shot interval settings Off, 200 ms, 500 ms, or 800 ms
ICD cooling levels 1–3
Internal cooling Air cooling
Display 10.1-inch LCD touchscreen
Dimensions 389 mm W × 856.4 mm L × 1604.1 mm H
Weight 47 kg
Electrical classification Class I, Type BF applied part
Power supply Single-phase AC 100–120 V, 50/60 Hz
Power consumption 1 kVA
RF activation Handpiece finger switch or foot switch
Treatment electrode Disposable Effector
Patient circuit Disposable patient return pad

Specifications may differ by device version and market configuration. Confirm the final specification sheet before ordering.

Training and support

Video training and supporting documentation cover system setup, Effector replacement, patient return pad connection, treatment settings, ICD cooling, and impedance synchronization. Materials also address operating precautions, cleaning, maintenance, and basic troubleshooting.

Operators should review the supplied documentation and complete the required training before using the equipment.

The machine comes with a one-year warranty and lifetime remote technical support. Remote assistance is available for setup, operating questions, troubleshooting, and maintenance. Warranty coverage, exclusions, replacement parts, and service procedures follow the terms supplied with your order.

Inspection and shipping

Each machine is inspected and tested before dispatch.

Shipping costs, delivery options, and trade terms depend on your destination and order configuration. ICD cooling medium may require separate shipping arrangements or may be restricted by the carrier. These details will be confirmed before the order is finalized.

Frequently asked questions

How many Effectors come with the machine?

The standard package includes 40 Effectors: 10 each of Effector 05, 10, 40, and 60.

How much do replacement Effectors cost?

Reference prices are USD 400 for four Effectors and USD 600 for eight. Contact us to confirm current pricing and shipping costs.

Are the patient return pads reusable?

No. They are disposable and intended for single use. Five pads are included with the machine. A replacement pack of 30 pads has a reference price of USD 150.

Can you ship the cooling medium to my country?

Availability depends on the destination and carrier requirements. The standard allocation is four 800 ml bottles where shipping is permitted. We will confirm the arrangement before you place your order.

Are training and manuals included?

Yes. Video training and operating documentation are included, covering setup, operation, treatment settings, maintenance, and basic troubleshooting.

Can I order consumables later?

Yes. Replacement Effectors, disposable patient return pads, and other compatible consumables are available for ongoing supply.

Do you offer OEM branding or distributor options?

OEM branding, bulk orders, and distributor cooperation are available on request. Minimum order quantities, pricing, configuration, and regional arrangements depend on the project.

How is shipping calculated?

Shipping is quoted according to the destination, package details, carrier, and delivery terms. Cooling medium may require a separate arrangement.

Request an itemized quote

Send us your destination country, business type, treatment requirements, and expected order quantity.

Your quotation will confirm the machine configuration, included consumables, replacement prices, cooling-medium availability, shipping terms, training, and warranty coverage. For OEM or distributor inquiries, include your branding requirements and target market.

Request Pricing and Shipping Details

Contact Us on WhatsApp

Shipping & Delivery Information

Estimated Delivery Time
Orders are usually delivered within 3–8 business days after payment, depending on local delivery conditions.

Shipping Methods
We work with reliable international couriers to ensure fast and safe delivery:

  • Express (DHL, UPS, FedEx, TNT, EMS): 5–10 business days.
    Note: Customs clearance and import duties are not included. Customers are responsible for these costs.

  • Air Mail: 10–18 business days.
    In most cases, customs clearance and taxes are included.  Because in certain countries, clearance may be difficult, so please confirm with us before choosing this option.

  • Sea Freight: 1–2 months (some destinations may take longer than 2 months).
    This option generally includes customs clearance and duty tax. We recommend sea shipping if your order is not urgent and you prefer a lower shipping cost.

Shipping Fee
The shipping cost is calculated based on the weight, dimensions, and destination of your order.

Tracking
A tracking number will be provided once your order has been shipped.

Tracking number will offered to you once shipped.  Read Full shipping policy.

We offer a 30 day money back guarantee for all products, read full refund policy.

Mico Aes Technology Co,.Ltd, based in China, Guangzhou, we have 5 factories with different production lines, one for diode laser machines, second for hifu machines, third for hydro facial devices, and fourth for emszero equipments, and fifth for co2 laser and pico laser machines. We are carefully monitoring the manufacturing processes and quality control checks every single machine before sending out to the shipping company. Mico Aes employees also frequently visit each of the factories to do random quality inspections to ensure our premium standards are met.  Learn More Details >>>

  • Manufacturing & Quality Control

    • Strict Manufacturing Process: Every machine is carefully monitored and inspected.
    • 100% Personal Inspection: Each product undergoes thorough quality checks before shipping.
    • Random Factory Inspections: Mico Aes employees conduct frequent site visits for quality assurance.
  • High-Quality Parts

    • Global Sourcing: Components from trusted suppliers in the USA, Germany, Japan, and Korea.
    • In-House Manufacturing: Some parts are produced in Mico Aes factories to meet high-quality standards.

We have certificates of CE, Rohs, FCC, and FDA, and patents of design.     Full certificates

certificates of Mico Aes

Mico Aes is committed to providing the best quality salon equipment. Whether it’s for your business or for your personal use, you need your machines to perform effectively and reliably for years to come.

  • Warranty period for main machine: 1 year from date of delivery
  • Warranty period for spare parts: 3 months from date of delivery
  • Lifelong Maintenance Support after the warranty period: Mico Aes will continue to provide free technical advice and parts at cost.

Read Full Warranty Policy

Request Technical Support

To ensure you achieve the best results for your clients, we provide complete access to a wide range of educational resources, including user manuals, treatment videos, protocols, and marketing materials. These resources are designed to help you understand your new equipment and promote your services effectively.

We also offer complimentary certification (certificate that you can hang on the wall).

Contact us after you receive your delivery to schedule your training session by Zoom or FaceTime.

Ask a question about this product anytime.

We can accept payment through Paypal(less then 1000USD), Western Union, Money Gram, and T/T bank wire transfer.

Full Payment policys 

ROI Calculator



Shopping Cart
XERF-Style Dual Frequency 6.78 MHz + 2 MHz Monopolar RF MachineXERF-Style Dual Frequency 6.78 MHz + 2 MHz Monopolar RF Machine
Original price was: $8,999.00.Current price is: $6,999.00.
United States dollar ($) - USD
  • United States dollar ($) - USD
  • Euro (€) - EUR
  • Pound sterling (£) - GBP
- +
Scroll to Top